MANUAL
Safety instructions
The motor may only be operated after reading these safety instructions, failing to do so might cause serious harm.
• Do not operate a blind which in any way is damaged
• Charging of battery operated blinds, only with suitable chargers
• only operate the blind within the prescribed environmental situation
• the motor may only be used in combination with the recommended and suitable power source, originally supplied
with the blind.
• A remote control is considered NOT to be a children's toy
• window decoration motors should be replaced when the rated cycle limitation is reached
Never drop the
Never drill into
motor!
the motor!
Page 1 of 22
Do not immerse
Avoid
into liquid!
collisions!
version: 1.3

Advertisement

loading
Need help?

Need help?

Do you have a question about the PowerView M25T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LuxaFlex PowerView M25T

  • Page 1 MANUAL Safety instructions The motor may only be operated after reading these safety instructions, failing to do so might cause serious harm. • Do not operate a blind which in any way is damaged • Charging of battery operated blinds, only with suitable chargers •...
  • Page 2: Delivery Condition

    MANUAL PowerView® Roller Blind 18VDC The PowerView® M25T tubular motor is suited to be used with EOS® Xcell Roller Blinds from HunterDouglas. Roller Blind 1. Delivery condition As standard, no remote control or hub is connected to the motor. No limits are set. Motor is default set to roller blind motor type.
  • Page 3 MANUAL 1.1.1 Power up the motor by connecting the power cable to the battery wand or power supply. 1.1.2 Immediately Check the motor button LED sequence after start up. 1.1.3 LED sequence of motor set to LED sequence of motor set to Roller blind Twist®...
  • Page 4 MANUAL  Note This procedure can be skipped for a fresh out of the box motor. The motor will jog 2x when receiving any PowerView® command (e.g. Pressing the manual control button on the motor), to confirm no limits are set. 1.2.1 Remove power from the motor by disconnecting the power cable from the battery wand or power supply...
  • Page 5: Network Reset

    MANUAL 1.2.4 Press and hold the until the manual control button motor jogs 1x. The motor LED flashes red-orange after the motor jogs 1.2.5 Release the manual control button The end limits have been cleared. 1.3. Network reset This procedure will erase all network data stored in the motor, including Network ID and Group assignments. It will not clear the end limits.
  • Page 6 MANUAL 1.3.2 Release the after the manual control button second jog. The Network ID and Group assignments have been cleared. 2. Pairing a remote A PowerView® remote can control up to 6 individual groups of blinds (buttons 1 to 6 at the top of the remote). The instructions below assign a blind to group 1.
  • Page 7 MANUAL  IMPORTANT Watch out to perform steps 2.4 and 2.5 within 3 seconds! Press and hold the manual control button Press the  button. open The blind will jog 1x. Release the manual control button Press and hold the  button for 6 seconds.
  • Page 8 MANUAL 3. Checking motor direction IMPORTANT  Reversing motor direction is only possible with a fresh out of the box motor (no limits set) or when the end limits are reset. Before any limits are programmed, the motor direction has to be checked and reversed if needed. If the top or bottom Limit is already set, and the motor direction has to be reversed, perform a reset before continuing.
  • Page 9 MANUAL 3.1.3 Release the manual control button The motor LED turns red to acknowledge the motor is in program mode. 3.2. Check and confirm  IMPORTANT Watch out to perform steps 3.2.1 and 3.2.2 immediately after each other to avoid mechanical damage! Carefully read them first before executing! 3.2.1 Press the ...
  • Page 10 MANUAL 3.2.3 Press and hold the for 1 manual control button second to reverse motor direction. The blind will jog 1x to acknowledge the direction is reversed. 3.2.4 Continue with step 4.1.4 4. Setting end limits It doesn’t matter if you start with setting the open or the close limit first. In this description we start with the open (top) limit.
  • Page 11 MANUAL 4.1.2 Press the  button. open Make sure  group1 on the remote is selected. The blind will jog 1x. 4.1.3 Release the manual control button The motor LED turns red to acknowledge the motor is in program mode. 4.1.4 Use the ...
  • Page 12 MANUAL 4.1.5 Press and hold the  button for 6 seconds. stop DO NOT select a group on the remote! Keep pressing until the remote lights start blinking.  IMPORTANT Watch out to perform steps 4.1.6 and 4.1.7 within 3 seconds! 4.1.6 Press and hold the manual control button...
  • Page 13 MANUAL 4.1.9 Press and hold the  button for 6 seconds. stop Keep pressing until the remote lights stop blinking. The remote will exit programming mode automatically after 20 seconds. 4.1.10 The top limit is set!  Note To re-position the top limit of the blind, repeat step 4.1 Open limit (top) Page 13 of 22 version: 1.3...
  • Page 14 MANUAL 4.2. Close limit (bottom) 4.2.1 Press and hold the manual control button 4.2.2 Press the  button. close Make sure  on the remote is selected. group1 The blind will jog 1x. 4.2.3 Release the manual control button The motor LED turns red to acknowledge the motor is in program mode.
  • Page 15 MANUAL 4.2.4 Use the  ,  and  buttons to open stop close move the blind to the desired bottom position. Use the  and  arrow up arrow down buttons to fine tune the desired position. 4.2.5 Press and hold the  button for 6 seconds.
  • Page 16 MANUAL 4.2.7 Press the  button. close The blind will move to the top limit to acknowledge the bottom limit is set. 4.2.8 Release the manual control button The motor LED turns off. 4.2.9 Press and hold the  stop button for 6 seconds.
  • Page 17: Delivery Conditions

    MANUAL 4.2.10 The bottom limit is set!  Note To re-position the bottom limit of the blind, repeat step 4.2. Close limit (bottom) 5. Special motor functions This chapter describes how to activate special functions with a standard PowerView® remote control: When activating a PowerView®...
  • Page 18 MANUAL  IMPORTANT These special functionalities are only available from motor serial number 0020153 onwards. Always check the motor's serial number on the product label. 5.2. Enable Roller blind type & Disable slow scene speed 5.2.1 Select the right group on the remote. In our example, we select ...
  • Page 19 MANUAL 5.2.3 Remove power from the motor by disconnecting the power cable from the battery wand or power supply and wait for 20 seconds. Do not forget this step!The motor needs to reboot to activate the function. 5.3. Enable Roller blind type 5.3.1 Select the right group on the remote.
  • Page 20 MANUAL 5.3.3 Remove power from the motor by disconnecting the power cable from the battery wand or power supply and wait for 20 seconds. Do not forget this step!The motor needs to reboot to activate the function. 6. Motor control button LED The motor control button LED gives an indication of the motor status.
  • Page 21: Important Notice

    MANUAL End limits reset (factory default), chapter 1.2 Network reset on manual control button release, chapter 1.3. Blind type: Roller blind Network reset on manual control button release, chapter 1.3. Blind type: Twist® Roller Blind Battery operation Low battery indication (< 11.0V). The blind will run in slow mode and can only be send upwards.
  • Page 22 MANUAL specifications applicable at the time of sale, in accordance with its standard warranty terms. Testing and other quality control techniques are used to the extent Hunter Douglas deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed.