Steps
9. Remove motor and cross flow blade
a
Remove the screws fixing motor clamp
and then remove the motor clamp.
Remove the screws at the connection
b
place of cross flow blade and motor; lift
the motor and cross flow blade upwards
to remove them.
Remove the bearing holder sub-assy.
Remove the screw fixing step motor and
then remove the step motor.
62
Procedure
Holder
sub-assy
Service Manual
Screws
Motor clamp
Cross flow
Screw
Motor
Screws
Step motor