Putting Into Operation - Kränzle Round Cleaner UFO Operating Manual With Spare Parts List

Ø 300 mm/stainless steel ø 350 mm
Hide thumbs Also See for Round Cleaner UFO:
Table of Contents

Advertisement

Available languages

Available languages

Putting into operation

Attach Round Cleaner UFO to the safety trigger gun
Instead of the cleaning lance please assemble Round Cleaner UFO at the trigger
gun with safety catch of your high-pressure cleaner. Always wear suitable protective
clothing and gloves when working with the Round Cleaner UFO.
The Kränzle Round Cleaner UFO can be operated with hot water of
max. 60 °C. Attention! Danger of scalding! Only touch metal parts
wearing gauntlets. Make sure to wear protective clothng!
No other persons or animals may be in the working area/near the
cleaning head.
Ensure a secure stand (danger of recoil) and hold the safety trigger gun
firmly with the extension tube or handle.
During operation the plug coupling must not be actuated/ touched!
High risk of injury!
Prior to insertion, check plug coupling connection of lance for
cleanliness (sand, dirt ..) and use clear water to clean, if necessary.
Impurities may damage the sealing in the plug coupling.
Accessories may only be connected to a Kränzle-approved trigger gun
with safety catch.
26
1.
First pull back the retaining sleeve
of the safety trigger gun, then
insert lance into the plug coupling
sconnection of the safety trigger gun.
2.
After insertion of the lance, release
retaining sleeve and make sure that
the lance is in a secure position.
Grease quick release nipple regularly
using acid-free grease.
Putting into operation
Floor cleaning
The Round Cleaner UFO is particularly suitable for cleaning plane surfaces like
carriage gateways, terraces etc.
Mount the Round Cleaner instead of the spray lance to the safety trigger gun
of your high-pressure cleaner.
Place the Round Cleaner to a non-sensitive surface, e.g. asphalt.
Set the pressure on your HP-cleaner in such a way that the appliance does not lift
off when moved forwards or backwards.
When cleaning sensitive surfaces try out the Round Cleaner on a barely visible spot
first and adjust the pressure so that the surface is not damaged.
Do not exceed max. pressure (see technical data).
No other persons or animals may be in the working area/near the
cleaning head.
Ensure a secure stand (danger of recoil) and hold the safety trigger gun
firmly with the extension tube or handle.
During operation the plug coupling must not be actuated/ touched!
High risk of injury!
The Kränzle Round Cleaner UFO can be operated with hot water of
max. 60 °C. Attention! Danger of scalding! Only touch metal parts
wearing gauntlets. Make sure to wear protective clothng!
max. working angle 45°
EN
27

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Round Cleaner UFO and is the answer not in the manual?

This manual is also suitable for:

418554188041850418814185141890 ... Show all

Table of Contents