Risco RP128EZ01 Manual
Risco RP128EZ01 Manual

Risco RP128EZ01 Manual

Single zone expander

Advertisement

Single Zone Expander (RP128EZ01)
The RISCO RP128EZ01 is a Single Zone Expander that enables to connect any detector to RISCO system
BUS. Using the BUS connection you can ease your installation by connecting any detector in parallel
connections from any point along the wiring route. In addition you can define any detector with one of
the following zone terminations supported by the panel: NO, NC, EOL, DEOL, TEOL.
The following instructions explain how to connect to the RP128EZ01 the ProSYS.
Notes:
1. Up to 32 Single Zone Expanders can be installed on the ProSYS main BUS.
2. Up to 128 Single Zone Expanders can be assigned to the ProSYS using the BUS Zone Expander.
The following instructions explain how to connect a detector to the ProSYS BUS using the RP128EZ01.

Installation

1.
Set the RP128EZ01 ID number (1-32) using DIP switches 1-5.
 SW1 (1 - 5): ID switches. Defines the Single BUS Zone Expander ID number
 SW1 - 6: Not used
ID
DIP - 1
1
Off
2
On
3
Off
4
On
5
Off
6
On
7
Off
8
On
9
Off
10
On
11
Off
12
On
13
Off
14
On
15
Off
16
On
2.
Wire the RP128EZ01 BUS wires Red, Black (COM), Yellow(BUS) and Green (BUS) to the
ProSYS BUS.
Notes:
For maximum operation stability, it is best NOT to exceed a total of 300 meters (1000 feet) of wiring from the
ProSYS BZ1 to the ProSYS panel or to the BUS Zone Expander.
 Wiring RP128EZ01 to the Main BUS
DIP - 2
DIP - 3
DIP – 4
Off
Off
Off
Off
Off
Off
On
Off
Off
On
Off
Off
Off
On
Off
Off
On
Off
On
On
Off
On
On
Off
Off
Off
On
Off
Off
On
On
Off
On
On
Off
On
Off
On
On
Off
On
On
On
On
On
On
On
On
DIP - 5
ID
DIP - 1
Off
17
Off
Off
18
On
Off
19
Off
Off
20
On
Off
21
Off
Off
22
On
Off
23
Off
Off
24
On
Off
25
Off
Off
26
On
Off
27
Off
Off
28
On
Off
29
Off
Off
30
On
Off
31
Off
Off
32
On
-1-
DIP - 2
DIP - 3
DIP - 4
Off
Off
Off
Off
Off
Off
On
Off
Off
On
Off
Off
Off
On
Off
Off
On
Off
On
On
Off
On
On
Off
Off
Off
On
Off
Off
On
On
Off
On
On
Off
On
Off
On
On
Off
On
On
On
On
On
On
On
On
DIP - 5
On
On
On
On
On
On
On
On
On
On
On
On
On
On
On
On

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RP128EZ01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Risco RP128EZ01

  • Page 1 Single Zone Expander (RP128EZ01) The RISCO RP128EZ01 is a Single Zone Expander that enables to connect any detector to RISCO system BUS. Using the BUS connection you can ease your installation by connecting any detector in parallel connections from any point along the wiring route. In addition you can define any detector with one of the following zone terminations supported by the panel: NO, NC, EOL, DEOL, TEOL.
  • Page 2  Wiring RP128EZ01 to BUS Zones Expanders Notes: When connecting RP128EZ01 to a BUS Zone Expander wire the RP128EZ01 wires to the relevant BUS zone expander's terminals marked as TO DEVICE. Wire the zone wires, Black and White, to the detector's terminals according to the RP128EZ01 required termination.
  • Page 3 The bottom line in the display shows "(0:yy) Type: None". In the 0:yy designation, the 0 represents that the RP128EZ01 is on the main unit and is not assigned to a BUS Zone Expander. The yy represents the RP128EZ01 ID number (up to 32) as set by its DIP switches.
  • Page 4 The display shows "(x:yy) Type: None" . In the x:yy designation, the x represents the BUS Zone Expander ID number and the yy represents the RP128EZ01 ID number that is connected to the zone expander, as set by the RP128EZ01 's DIP switches.