PIR Wall Black
89430
7. The hole is a reserved Leaking hole(Min. 4.0x5.0mm), if use the cable hole at the back plate,
you can open it if necessary.
8. If use the cable hole at the side of the sensor, the leaking hole must be opened.
■FITTING THE UNIT (Referring to the above figure)
Before commencing any electrical work, ensure mains supply cables are isolated by switching
off and removing the relevant fuse.
1. Unscrew the screws①, remove the back plate and terminal block
2. Affix the back plate to the mounting surface with screw② (supplied)
3. Connecting the main power wires and "load" wires to the terminal block (see the relative
symbols), the wires must pass through the rubber gasket.
4. Re-fit the terminal block and screws①
After finishing the fitting operation, you can adjust the detection area and working state of
PIR sensor.
■WALK TESTING:
When power is switched on to the 89430, the 89430 detector will enter into a "WARN-UP"
period for approximately 30 seconds (within 1 minute) and then automatically change into
"AUTO MODE". Whilst in the AUTO MODE, you can then carry out a Walk-Test by placing
the LUX control to day position ( ) and the TIME control to minimum ( - ). Once the 89430
sensor receives a valid trigger signal (such as movement of a human body) within its detection
area, the lamp(s) (load) will be turned on for the pre-set period of time. You will be able to
determine the detection area by walking slowly.
After completing the walk-test, set the LUX KNOB to the night position to
ensure 89430 only operates at night and set TIME KNOB to the desired
"ON' time.