Technical Specification; General Description; Measuring Method - Zeta ZetaGas GS-220.BC.V..MET.100 Operation Manual

Combustible gas detector
Table of Contents

Advertisement

Technical specifications

General description:

A stationary gas detection system consists of a detector (transmitter) and a central controller. The
detector and the controller are connected with a cable. The detector converts the gas concentration into
an electric measurement signal and transmits it via the cable for processing to the controller.
Gas detectors GS-220.BC.V.ZETA are intended for detection of explosive and toxic gases. They are
suitable for detection of different gases depending on the gas detection element.

Measuring method:

The following measuring methods are used:
1. Catalytic sensors for measurement of explosive gases.
2. Electrochemical sensors for toxic gases.
3. Infrared sensors for CO2.
4. Semiconductor sensors for refrigerant gases.
Table. 1
DETECTED GASES
Gas feed
POWER SUPPLY
Working voltage
Power Consumption
OUTPUT SIGNAL
GS-220.BC.V.ZETA
ENVIRONMENTLE CONDITIONS
Working temperature
Humidity range
Atmospheric pressure range
MECHANICAL
Dimensions
Weight
Enclosure material
Ingress protection
Cable connection
CERTIFICATION
Conformity mark
ATEX certification
See Table. Ordering codes
Diffusion
12 – 30 VDC
3W
4 – 20mA
-20 - + 50ᵒC
10 – 90% R.H.
800 – 1100 hPa
155 x 120 x 48mm
0,320kg
Aluminium
IP65
Cable gland(s) M16 (M20)
CE
ATEX II 2G Ex d (ib) ma IIC T4 Gb
ATEX II 2D Ex tb (ib) ma IIIC T135oC IP65 Db
5

Advertisement

Table of Contents
loading

Related Products for Zeta ZetaGas GS-220.BC.V.ZETA.MET.100

Table of Contents