Download Print this page
Agilent Technologies Turbo-V 9699375 Instructions Manual

Agilent Technologies Turbo-V 9699375 Instructions Manual

Vibration dampers

Advertisement

Quick Links

Agilent Turbo-V Vibration Dampers
Instructions

Advertisement

loading

Summary of Contents for Agilent Technologies Turbo-V 9699375

  • Page 1 Agilent Turbo-V Vibration Dampers Instructions...
  • Page 2: Warranty

    Agilent disclaims all © Agilent Technologies, Inc. 2021 not correctly performed or adhered to, warranties, either express or implied, could result in damage to the product...
  • Page 3 Turbo-V Vibration Dampers Extremely low vibration amplitudes at the turbopump inlet flange are required for some sensitive applications, even lower than the already low levels normally present in the turbopump. Typically scanning electron microscopes, or other analytical instruments require additional dampening of the vibration amplitude. To further reduce the residual amplitude, a vibration damper is provided.
  • Page 4 With an ISO flange, connect the Turbo vibration damper using the provided center ring and the clamp screws only (the claw grips are not used). Table 1 reports the outline dimensions and the mounting requirements of the Turbo vibration damper. Table 1 Turbo-V Vibration Dampers outline dimensions Turbo Vibration...
  • Page 5 Turbo Vibration Dampers Turbo Pump Applicability MODEL INLET FLANGE MODEL DESCRIPTION X3513-64008 TwisTorr 305 FS, Air Cooling X3513-64012 TwisTorr 305 FS, Water Cooling X3513-64060 TwisTorr 305-ICQ, High Throughput, Water Cooling, RS485 X3513-64061 TwisTorr 305-ICQ, High Throughput, Air Cooling, RS485 X3513-64066 TwisTorr 305-IC SF, Dual Flow, Air Cooling, RS485A X3513-64067 TwisTorr 305 SF Dual Flow, Air Cooling...
  • Page 6 Turbo Vibration Dampers Turbo Pump Applicability MODEL INLET FLANGE MODEL DESCRIPTION G8701A TPS-mobile #012, #025 9698813 TV750 On board ISO-K 9698818 TV750 On board ISO-F 9696013 TV750 Rack ISO-K 9696018 TV750 Rack ISO-F 9698840 TV1001 Nav. kit ISO 9698933 TV1001 Nav. pump ISO 9699346 ISO200 X3511-64007...
  • Page 7 Table 3 Turbo-V Vibration Dampers CFF flanges Turbo Vibration Dampers Turbo Pump Applicability MODEL INLET FLANGE MODEL DESCRIPTION 9699376 CFF 4 ½" X3502-64172 TwisTorr 74 FS CFF X3502-64002 TwisTorr 84 FS CFF X3580A TPS-compact #010, #022 G8701A TPS-mobile #010, #022 G8700A TPS-bench #010, #022 G8703A...
  • Page 8 Turbo Vibration Dampers Turbo Pump Applicability MODEL INLET FLANGE MODEL DESCRIPTION 9699335 CFF 8" X3513-64003 TwisTorr 305 IC, 485A Air X3513-64007 TwisTorr 305 IC, 485A Water X3513-64019 TwisTorr 305-IC, 485P Air X3513-64023 TwisTorr 305-IC, 485P Water X3513-64027 TwisTorr 305-IC, 232 Air X3513-64031 TwisTorr 305-IC, 232 Water X3513-64011...
  • Page 14 Request for Return Form United States India (Sales) India (Service) Agilent Technologies India Pvt. Ltd. Agilent Technologies Agilent Technologies India Pvt. Ltd. C-Block, RMZ Centennial Plot Number- 8A, 8B, 8C, 8D, Unit Nos 110- 116, & Part of 101 & 109...
  • Page 15: In This Book

    In This Book The manual describes the following: Instructions for Turbo-V Vibration Dampers  www.agilent.com © Agilent Technologies, Inc. 2021 Edition D.00, 01/21 *87-900-814-01* 87-900-814-01...