Certification
6.2 EMC and Environmental Type Tests
61000-4-5
61000-4-6
61000-4-8
61000-4-29
61000-4-11
61000-4-12
61000-4-16
61000-4-17
IEC 60255-5
28
Test
IEC
Surge
IEC
Induced (Conducted) RFI
IEC
Magnetic Field
IEC
Voltage Dips and Interrupts
IEC
IEC
Damped Oscillatory
IEC
Mains Frequency Voltage
IEC
Ripple on DC Power Supply
Dielectric Strength
HV Impulse
Description
AC Power
ports
Earth
ground ports
Signal ports
DC Power
ports
AC Power
ports
Signal ports
DC Power
ports
AC Power
ports
Earth
ground ports
Enclosure
ports
DC Power
ports
AC Power
ports
Signal ports
DC Power
ports
AC Power
ports
Signal ports
DC Power
ports
DC Power
ports
Signal ports
DC Power
ports
AC Power
ports
Signal ports
DC Power
ports
Test Levels
±4 kV
±4 kV
±4 kV line-to-earth,
±2 kV line-to-line
±2 kV line-to-earth,
±1 kV line-to-line
±4 kV line-to-earth,
±2 kV line-to-line
10 V
10 V
10 V
10 V
40 A/m continuous,
1000 A/m for 1 s
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
30% for 1 period,
60% for 50 periods
100% for 5 periods,
100% for 50 periods
2.5 kV common, 1 kV
differential mode @ 1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
30 V Continuous,
300 V for 1 s
30 V Continuous,
300 V for 1 s
10%
2 kVAC  (Fail-
Safe Relay output)
1.5 kVDC
2 kVDC
5 kV  (Fail-Safe
Relay Output)
5 kV
Installation Manual, 01/2021, C79000-G8976-1023-05
Severity
Levels
4
4
4
3
4
3
3
3
3
 
 
 
 
3
3
3
4
4
3
 
 
 
 
 
RUGGEDCOM RS8000T