Electrical Installation; Power Supply; Backup Battery - Cr2032; Ethernet - Bodet NETSILON 7 AC Quick Start Manual

Table of Contents

Advertisement

2.4 Electrical installation

All cables must be securely attached to the chassis before being connected to the
various terminal blocks in order to prevent traction on connections. Conductors on the
same circuit must be attached to each other close to the terminal block to avoid reduced
isolation should one of the terminals become loose.
The equipment must only be connected to the power supply
once it has been securely mounted in the 19" destination rack.

2.4.1. Power supply

Power supply management according to version:
>
Netsilon 7 / 9 / 11 (100-240V
> Connect the power cord to the AC IN connector at the rear of the device.
>
Netsilon 7 / 9 / 11 (22-30V
> Connect a DC cable and observe the polarity indicated at the rear of the device.
>
Netsilon 7 / 9 / 11 (100-240V
> Connect the power cord to the AC IN connector and/or a DC cable, being careful to observe the
correct polarity indicated at the rear of the device.
>
Netsilon 7 / 9 / 11 (100-240V
> Connect the power cord(s) to the AC IN connector(s) at the rear of the device.
The functional earthing terminal can be attached to the cabinet frame (optional).
The DC IN power supply must be protected upstream by a 6.3 AT fuse.
When several Netsilon units are powered from the same power supply, protect each DC IN input with
a separate 6.3 AT fuse.
Be careful to observe the correct polarity indicated at the rear of the device.

2.4.2. Backup battery - CR2032

If replacing the CR2032 battery, it is essential to observe the polarity, as indicated on the slot of the battery.
Caution :
>
There is a risk of explosion if the battery is replaced by a non-compliant battery. Use only batteries
recommended by the manufacturer.
>
Dispose of used batteries in accordance with the instructions given on our website.
>
The accumulator must not be swallowed – risk of chemical burns.
>
Always keep new and discharged accumulators out of the reach of children.
>
This product contains a button battery or accumulator. If swallowed, the button battery or accumulator
can cause severe internal burns which may be fatal.
>
If you suspect that an accumulator cell may have been ingested or inserted anywhere in the body, you
must seek immediate medical attention.

2.4.3. Ethernet

The ETH0 Ethernet port, accessible on the rear panel of the device, enables easy connection to routers, switches
or hubs.
1) Use a shielded CAT.5E or CAT.6 cable Ethernet cable (RJ45)
2) Connect the Ethernet network cable to the RJ45 connector on the Netsilon rear panel.
The product is commissioned by activating the ON/OFF switch on the rear panel of the device.
The Bodet company strongly recommends connecting and using Netsilon exclusively on a private
network (VLAN).

2.4.4. Alarm relay circuits

For the relay circuits, provide protection by means of a fused disconnect switch or circuit breaker of 1A maximum.
Maintenance must be performed with power off. Disconnect the power supply and relay circuits under hazardous
voltage.
10
): mains power supply only.
): direct current only.
+ 22-30V
): mains power supply and/or direct current power supply.
+ 100-240V
): dual mains power supply.