Download Print this page

Technical Data - BRAHMA EUROBOX Series Manual

Automatic control systems for gas burners and gas burning appliances with or without fan (manual reset)

Advertisement

TABLE 1
CM191N
*
SM191N
*
SM192N
CM381N
*
CM391N
*
SM152N
SM592N
MM191N
*
MM192N
NOTE: (A) Box type xxxxxx.1 – xxxxxx.2
(B) Box type xxxxxx.3 – xxxxxx.4

TECHNICAL DATA

Power supply:
on request:
Operating temperature range:
Humidity:
Protection degree:
socket NG
socket P/R
Times:
-purge time (TW):
TW for type SM152N
time at start-up (TS):
response time in case of flame failure
The times appearing on the product label correspond to guaranteed
values. Actual times may differ from declares ones, as waiting and
pre-purge time may be longer and safety time shorter than their
nominal values.
Power consumption at start-up:
atmospheric burner
atmospheric fan-assisted burner
Power consumption during operation: atmospheric
burner
atmospheric fan-assisted burner
Max contact rating:
-
Thermostat:
- EV1:
- EV2:
- EVG:
-
Fan:
-
Lockout signal:
-
Auxiliary contact:
-
External ignition device:
Max cable length for
external components:
Internal fuse rating:
External fuse rating:
Flame monitoring:
The flame detection device exploits the rectification property of the
flame (ionization); the device is not provided with any protection
impedance and is therefore not safe against the risk of electric
shock.
2/6
BURNER
OPTIONS
*
*
*
*
*
*
*
*
*
*
*
*
*
*
230V 50/60Hz
110/120V
50/60Hz
-20C
+60C
95% max at 40° C
IP 40 (after installation)
IP 00
waiting/pre
1,5..40 s
3..40 s
safety
3..60 s
 1 s
10VA
12VA
7VA
9VA
Imax
cos ≥ 0.4
4A
cos ≥ 0.4
0.5A
cos ≥ 0.4
0.5A
cos ≥ 0.4
0.5A
cos ≥ 0.4
1A
0.5A
cos = 1
cos ≥ 0.4
0.5A
cos ≥ 0.2
1.5A
1 m
5A
slow-blow
3.15A
fast-blow
44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวี ว ั ฒ นา กทม. 10170.
website:
https://www.add-furnace.com/
Line ID: @add11 e-mail: add028883472@gmail.com
RESET
(B)
(A)
(A)
(B)
(A)
(B)
(A)
(A)
(B)
(A)
*
(B)
(A)
*
(B)
(A)
*
(B)
(A)
(1): The auxiliary contact is not type SELV (Safety Extra Low Voltage) and is therefore
not suitable to control SELV circuits.
(2): Flame failure during TS causes spark restoration.
(3): Label showing the marking "EN298:2003 compliant" and part reference provided with
suffix N.
-
Min ionization current:
on request:
-
Recommended ionization current: 35 times the min one
-
Max cable length:
-
Min insulation resistance of detection
cable and electrode to earth:
-
Max electrode stray capacitance:
-
Max short-circuit current:
-
Max ionization current (230 V 50 Hz):
Ignition:
-
Ignition voltage:
-
Spark repetition rate:
-
Max cable length:
-
Recommended spark gap:
-
Power consumption:
-
Spark energy:
Weight:
with socket P or R:
with socket NG or MG:
Control units for special applications:
Upon request it is possible to meet particular requirements
regarding times, spark repetition rate, min ionization current and
operating cycle.
CONSTRUCTION
The plastic casing protects the control unit from any damage
resulting from impacts, tampering, dust and contact with the
external environment.
A particular construction technique, consisting of four PCBs
assembled together to form a "box" structure, has enabled
considerably reduce the dimensions of the device.
A varistor protects the control unit from any voltage transients
which may arise in the mains supply.
An inbuilt fuse protects the internal relays of the unit in case of short
circuit on the control outputs (valves, fan and lockout signal). As
this fuse is not accessible, the unit will have to be protected by an
external fast-blow fuse suitable to the loads connected and never
exceeding 3,15A.
โทร: 02-888-3472
CONNECTION
AMCLXN
*
*
*
AMCLXN
*
AMCLXN
*
*
*
FMCLXN
*
*
*
FMCLXN
*
AMCLXN
*
*
*
AMCLXN
*
*
*
AMCLXN
*
*
*
AMCLXN
*
*
*
8KV with 30pF load
*
*
*
*
*
*
*
*
*
0.5A
1.2A
1 m
 50M
 1nF
 200A AC
8A DC
25Hz
2m
2-4mm
2.5VA
15mJ
220g
275g
to
15756_r02

Advertisement

loading

This manual is also suitable for:

Cm191nSm191nSm192nCm381nCm391nSm152n ... Show all