BRAHMA EUROFLAT Series Manual

Automatic gas burner control systems for gas burners and gas burning appliances with or without fan monoelectrode with external ignition device

Advertisement

Quick Links

EUROFLAT SERIES
TYPES
MT11 MT31
AUTOMATIC GAS BURNER CONTROL
SYSTEMS FOR GAS BURNERS AND GAS
BURNING APPLIANCES WITH OR
WITHOUT FAN MONOELECTRODE WITH
EXTERNAL IGNITION DEVICE.
3999_r01

Application

This range of electronic gas burner control systems has
been designed specifically for atmospheric and fan assisted
burners for intermittent operation (systems for non-
permanent operation).
These types of automatic burner control units differ from the
standard model essentially in the operating cycle and in the
features of the ignition-detection device. Due to the design
and the technical-structural characteristics, the controls of
this series can be used in general in gas firing installations
with atmospheric burner.

Features

Table 1 shows the main features of this series. Other
important features are:
− in accordance with EN298 (European standard for
automatic gas burner control systems);
− flame monitoring by the rectification property of the
flame: ionization;
− electrical
service
life
− two independent safety contacts in series on the gas
valve output;
− electronic ignition device (transformer TC1 – TD1
series).
T AB L E 1
B UR NE R
MT 11
*
MT 31
*
at
max.
loading
>250.000
*
AMCLXN
*
FMCLXN
1/4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EUROFLAT Series and is the answer not in the manual?

Questions and answers

Summary of Contents for BRAHMA EUROFLAT Series

  • Page 1 EUROFLAT SERIES TYPES MT11 MT31 AUTOMATIC GAS BURNER CONTROL Application This range of electronic gas burner control systems has SYSTEMS FOR GAS BURNERS AND GAS been designed specifically for atmospheric and fan assisted BURNING APPLIANCES WITH OR burners for intermittent operation (systems for non- WITHOUT FAN MONOELECTRODE WITH permanent operation).
  • Page 2 TECHNICAL DATA Supply Voltage: 230V∼ 50-60Hz Operating temperature range: -20° C +60° C Ambient humidity: 95% max at 40° C Protection degree: IP 00 Times: Waiting or pre- purge time (TW): 1,5/3/5/10/20/30/40 s - Safety time (TS): 3/5/8/10/20/50/60 s - Ignition time (TSP): (40% di TS) s - Drop out time on running flame failure: <...
  • Page 3 − if the attempt to start occurs without the gas supply the The controls are prearranged to operate with only one electrode for ignition and flame detection (the ignition control performs a non-volatile or volatile lock-out after electrode also makes the flame detection function by means −...
  • Page 4 DEVICE SIGNAL SWITCH SIGNAL ATTENTION -> Company Brahma S.p.A. takes no responsibility for any damage resulting from Customer's tampering with the device. BRAHMA S.p.A. Via del Pontiere, 31 37045 Legnago (VR) – ITALY Tel. +39 0442 635211 – Fax +39 0442 25683 2011/06/07 subject to amendments without notice http://www.brahma.it...

This manual is also suitable for:

Euroflat mt11Euroflat mt31

Table of Contents