Savant DOR-SMS-00 Deployment Manual

Entry service using 2n door stations
Hide thumbs Also See for DOR-SMS-00:

Advertisement

Entry Service using 2N Door Stations
DOR-SMS-00 | DOR-FMS-00 | DOR-SMB-00 | DOR-FMB-00
DOR-SM0S-00 | DOR-FM0S-00 | DOR-SM0B-00 | DOR-FM0B-00
DOR-HDSMKB-00
Deployment Guide
Document Number:
009-1540-00
Document Date:
October 2018
Document Supports:
da Vinci 8.9
Copyright © 2018 Savant System, LLC
45 Perseverance Way, Hyannis, MA 02601
Savant.com
| 508.683.2500

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DOR-SMS-00 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Savant DOR-SMS-00

  • Page 1 Entry Service using 2N Door Stations DOR-SMS-00 | DOR-FMS-00 | DOR-SMB-00 | DOR-FMB-00 DOR-SM0S-00 | DOR-FM0S-00 | DOR-SM0B-00 | DOR-FM0B-00 DOR-HDSMKB-00 Deployment Guide Document Number: 009-1540-00 Document Date: October 2018 Document Supports: da Vinci 8.9 45 Perseverance Way, Hyannis, MA 02601 Copyright ©...
  • Page 2: Table Of Contents

    Appendix A: Switch Configuration ........24 Appendix B: Door Lock Service .......... 26 Appendix C: External Camera Feeds .........27 Appendix D: Static IP Address ..........28 Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 3 Savant technical documentation can Read these instructions. be located by visiting Savant.com. Vendor documentation is supplied Keep these instructions. with the equipment. Heed all warnings.
  • Page 4: Introduction

    Vinci 8.9 or higher ............................... Door Station serial number ............................ Savant Development Environment (SDE/MacBook) ................... Ethernet network meeting Savant requirements ..................Power over Ethernet (PoE) 2. Deployment Steps Follow these steps to successfully deploy a 2N Door Station. This page can be used as a checklist to record which steps have been completed.
  • Page 5: Equipment Overview

    3. Equipment Overview This section gives a basic overview of the 2N Door Stations that Savant sells. For detailed information on the individual products see the Documentation tab on the Integrator store on Savant.com. 3.1. Box Contents and Specifications Documentation is available on the Savant Customer Community, See the 2N Door Station Integration with Savant Application Note.
  • Page 6 ON: closed OR U < 1.5V Reset/Factory Reset button Reset Press button for <1s to reboot the unit RJ-45 female connector LAN (PoE) (optional PoE 802.3af) Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 7: Door Station (2N Ip Verso)

    Bluetooth Module (9155046) – RFID Card Reader 13.56MHz NFC Ready (9155042) Module Slot – Touch Display (9155036) – Keypad Module (9155031/9155031B) – Tamper Switch (9122038) Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 8 Reset/Factory Reset button Reset Press button for <1s to reboot the unit LED indicators Red/Green/Yellow Line Out Audio line out (1V Microphone connection Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 9: Heavy Gate Station (2N Ip Force)

    Active Output 8 to 12V DC max 400mA Out1 (PoE: 10V; adapter: power supply voltage minus 2V) External 12V 2A connection. RELAY1 OUT1 Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 10: Wiring And Connections

    IMPORTANT! The diagram above show the wiring for the Door Station. On the Single Height Door Station the wiring order is reversed, having the Negative terminal on the left side. Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 11: Power Connection

    4.5. Power Connection Savant strongly recommends using PoE. If PoE is not available a 12V 2A external power supply can be used. Pin 1 Positive Pin 2 Negative Pin 3 Ground 12V/2A IMPORTANT! The diagram above show the wiring for the Door Station and the Heavy Gate Station. On the Single Height Door Station the wiring order is reversed, having the Negative terminal on the left side.
  • Page 12: Door Station Configuration

    5. Door Station Configuration This section shows how to configure any of the Savant sold 2N Door Stations for use within a Savant System. 5.1. Connect/Login 5.2. Firmware Update To Connect and configure a 2N Door Station do the following: This process should only need to be done the first time the Door Station is setup.
  • Page 13: Services

    This is a max duration of the call before the intercom terminates the call. HELPFUL INFO: Setting the “Call Time Limit” to zero will make the call have an unlimited time. Click Save Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 14 Video Framerate 15 fps Video Bitrate 512 kbps MJPEG Video Parameters Video Resolution SXGA (1280x960) Video Framerate 15 fps Video Quality 13. Click Save. Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 15 Door Station it self. These credentials will be used later in the ONVIF setup. 20. Enable all User Privileges. 21. Click Save. Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 16: Hardware

    IMPORTANT! Motion/Noise Detection should not be enabled until the unit has been installed and Must have the sensitivity adjusted so the Host is not flooded with events (This will degrade system performance). Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 17: Blueprint

    6. Blueprint To add a 2N Door Station to a configuration there is one profile that works for all Savant supported 2N IP Intercom models. In an open Blueprint configuration do the following. Click Show Library. 12. Click Done. In the Search bar type 2N.
  • Page 18: Entry Service Screen Buttons

    After the Door Station has been placed in Blueprint with a control connection and services have been generated, custom buttons can be added to the Entry Service Screen in the Savant Pro App. In the example below, it will add a button to turn on a flood light that will be turned off by a timed trigger.
  • Page 19 Enter a Boolean state that the system will track the to determine if the Command or Toggle Command is sent. Follow Inverse of State Inverts when the button will use the Command and the Toggle Command. Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 20: Audio Interrupt Service (Ais)

    2N Door Station to create a AIS doorbell. For more detailed information on creating an AIS trigger see the Audio Interrupt Service (AIS) Configuration for Doorbells on the Savant Customer Community. In an open Blueprint configuration do the Following: Make an audio connection from the Host to the audio distribution system.
  • Page 21: Remote Calling

    To receive calls from the door station when the user is away from the local network there are some additional steps that must be completed. In order for the Savant Pro App to receive calls when the app is closed a notification must be created for each user that wishes to be notified. This example, shows how to configure a notification for whenever the call from the door station is placed.
  • Page 22: System Monitor

    This list displays the name of the device connected to the extensions. Device and connection information. Device Status See the Device Status below for more information Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 23 Current state of Relay 1. Relay 2: Current state of Relay 2. Output 1: Current state of Output 1. Output 2: Current state of Output 2. Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC 009-1540-00 | 181026...
  • Page 24: Appendix A: Switch Configuration

    Appendix A: Switch Configuration This section is only needed if the Door Station’s Relay or a GPIO is going to be used in the Savant configuration. Also if the 2N Door Station has a keypad and it is desired to have a key code to activate a Relay or an GPIO. This example of uses the output of the Door Station to supply voltage to a 3rd party door lock.
  • Page 25 * Requires IP Verso with touch display/keypad or the IP Force NOTES: – This table only describes the fields that are commonly used in Savant’s deployment. – For full information on switch features see the 2N IP Configuration Manual. Entry Service with 2N Door Stations Deployment Guide Copyright ©...
  • Page 26: Appendix B: Door Lock Service

    Select the Camera Mapping. Click Done. For more information on the Door Lock service see the Savant Pro 8 Door Lock Service Overview and the Savant Customer Community. Entry Service with 2N Door Stations Deployment Guide Copyright © 2018 Savant Systems, LLC...
  • Page 27: Appendix C: External Camera Feeds

    Appendix C: External Camera Feeds It’s possible to not use the internal camera of the door station for the camera feed shown in the Savant App for the Entry and Camera service for the door station. This is helpful if there’s another camera that has a better view of the entry.
  • Page 28: Appendix D: Static Ip Address

    Appendix D: Static IP Address Savant recommends using DHCP. If a static IP Address is required it can be set in the Door Stations admin web-UI. Once connected to the door station’s admin web-UI follow the steps below: Select System.
  • Page 29 Savant Systems, LLC. shall not be liable for any technical or editorial errors or omissions contained herein or for incidental or consequential damages resulting from the performance, furnishing, reliance on, or use of this material.

Table of Contents