April 2020 Document Supports: da Vinci 8.9 and Higher This document guides the installer through deploying, configuring, and adding a 2N Door Station and associated Entry Service to a Savant Pro System. Products supported by this document include the following: –...
Page 3
Savant technical documentation can Read these instructions. be located by visiting Savant.com. Vendor documentation is supplied Keep these instructions. with the equipment. Heed all warnings.
Vinci 8.9 or higher ............................... Door Station Serial Number ..........................Savant Development Environment (SDE/MacBook) ................... Ethernet network meeting Savant requirements ..................Power over Ethernet (PoE) 2. Deployment Steps Follow these steps to successfully deploy a 2N Door Station. This page can be used as a checklist to record which steps have been completed.
3. Equipment Overview This section gives a basic overview of the 2N Door Stations that Savant sells. For detailed information on the individual products see the Documentation tab on the Integrator store on Savant.com. 3.1. Box Contents and Specifications Documentation is available on the...
On Single Height door stations: Negative to Pin 1, Common to Pin 2, Positive to Pin 3. – While Blueprint allows for relay control directly, Savant recommends that relays are controlled using a 2N programmed “Switch” in the 2N’s web-GUI. This ensures the best possible user experience.
5. WebUI Configuration This section describes how to configure a supported 2N Door Station to be integrated into a Savant system. 5.1. Connect/Login 5.2. Firmware Update To connect the webUI, do the following: In a web browser, log into the door station to be configured: Find IP Address of the door station.
6. Blueprint Configuration To integrate a 2N door station to a Savant system, a blueprint configuration must be configured and uploaded to the host. In an open Blueprint configuration, do the following: Click Show Library. 10. Click Done. In the Search bar type 2N.
6.1. Entry Service Screen Buttons Custom buttons can be added to the Entry Service Screen in the Savant Pro App. This section describes how to create a button that open or close a 2N Door Station Switch via a press of a custom Entry Service Screen button.
Appendix A: Switch Configuration A Switch must be configured within the webUI if a 2N door station is used to control a relay or GPIO within the Savant configuration. This example uses the output of the door station to supply voltage to a 3rd party door lock.
Click the + Plus icon. Select the door station as the controller. 4. Select the location the Door Lock service will populate in on the Savant Pro App. Select Entity type. Enter the Switch address in the Door Lock Address field.
Appendix C: External Camera Feeds To use an external camera for the feed shown in the Savant Pro App and TrueControl II for the Entry and Camera service for the door station, the 2N web interface must be configured. Once connected to the door station via the web interface: Check the External Camera Enabled check box.
Appendix D: Static IP Address Savant recommends using DHCP reservation. If a static IP Address is required, it must be set in the door station web UI. Within the 2N door station web UI, follow the steps below: Uncheck Use DHCP Server.
Page 29
Savant Systems, LLC. shall not be liable for any technical or editorial errors or omissions contained herein or for incidental or consequential damages resulting from the performance, furnishing, reliance on, or use of this material.