Savant DOR-SMS-00 Deployment Manual

Entry service using 2n door stations
Hide thumbs Also See for DOR-SMS-00:

Advertisement

Entry Service using 2N Door Stations - Deployment Guide
Document Number:
009-1540-01
Document Date:
April 2020
Document Supports:
da Vinci 8.9 and Higher
This document guides the installer through deploying, configuring, and adding a 2N Door Station and associated Entry Service to a Savant Pro System.
Products supported by this document include the following:
DOR-SMS-00
DOR-FMS-00
DOR-SMB-00
DOR-FMB-00
DOR-SM0S-00
DOR-FM0S-00
DOR-SM0B-00
DOR-FM0B-00
DOR-HDSMKB-00
Copyright © 2020 Savant System, LLC
45 Perseverance Way, Hyannis, MA 02601
Savant.com
| 508.683.2500

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DOR-SMS-00 and is the answer not in the manual?

Questions and answers

Summary of Contents for Savant DOR-SMS-00

  • Page 1 April 2020 Document Supports: da Vinci 8.9 and Higher This document guides the installer through deploying, configuring, and adding a 2N Door Station and associated Entry Service to a Savant Pro System. Products supported by this document include the following: –...
  • Page 2: Table Of Contents

    Appendix A: Switch Configuration ................. 24 Appendix B: Door Lock Service ................26 Appendix C: External Camera Feeds ..............27 Appendix D: Static IP Address ................. 28 Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 3 Savant technical documentation can Read these instructions. be located by visiting Savant.com. Vendor documentation is supplied Keep these instructions. with the equipment. Heed all warnings.
  • Page 4: Introduction

    Vinci 8.9 or higher ............................... Door Station Serial Number ..........................Savant Development Environment (SDE/MacBook) ................... Ethernet network meeting Savant requirements ..................Power over Ethernet (PoE) 2. Deployment Steps Follow these steps to successfully deploy a 2N Door Station. This page can be used as a checklist to record which steps have been completed.
  • Page 5: Equipment Overview

    3. Equipment Overview This section gives a basic overview of the 2N Door Stations that Savant sells. For detailed information on the individual products see the Documentation tab on the Integrator store on Savant.com. 3.1. Box Contents and Specifications Documentation is available on the...
  • Page 6 < 1.5V Factory Reset button. Reset Press and hold for 2 seconds to reboot the unit. RJ-45 female connector. LAN (PoE) Optional: PoE 802.3af Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 7: Door Station (2N Ip Verso)

    Bluetooth Module (9155046) – RFID Card Reader 13.56MHz NFC Ready (9155042) Module Slot – Touch Display (9155036) – Keypad Module (9155031/9155031B) – Tamper Switch (9122038) Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 8 Factory Reset button. Reset Press and hold for 2 seconds to reboot the unit. LED indicators Red/Green/Yellow Line Out Audio line out (1V Microphone connection. Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 9: Heavy Gate Station (2N Ip Force)

    Active Output 8 to 12V DC max 400mA Out 1 PoE: 10V; adapter: power supply voltage minus 2V 12 V External 12V 2A connection. RELAY1 OUT1 Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 10: Wiring And Connections

    On Single Height door stations: Negative to Pin 1, Common to Pin 2, Positive to Pin 3. – While Blueprint allows for relay control directly, Savant recommends that relays are controlled using a 2N programmed “Switch” in the 2N’s web-GUI. This ensures the best possible user experience.
  • Page 11: Power Connection

    4.1. Power Connection Savant strongly recommends using PoE. If PoE is not available, a 12V 2A external power supply can be used. Pin 1 Positive Pin 2 Negative Pin 3 Ground 12V/2A Entry Service with 2N Door Stations Deployment Guide Copyright ©...
  • Page 12: Webui Configuration

    5. WebUI Configuration This section describes how to configure a supported 2N Door Station to be integrated into a Savant system. 5.1. Connect/Login 5.2. Firmware Update To connect the webUI, do the following: In a web browser, log into the door station to be configured: Find IP Address of the door station.
  • Page 13: Services

    4. Set Call Time Limit. This is a max duration of the call before the intercom terminates the call. HELPFUL INFO: Set the Call Time Limit to zero to for unlimited call time. Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 14 VGA (640x480) Video Framerate 15 fps Video Bitrate 512 kbps MJPEG Video Parameters Video Resolution SXGA (1280x960) Video Framerate 15 fps Video Quality Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 15 These credentials are different than the credentials used to log into the webUI. Note them down for later use. 18. Enable all User Privileges. 19. Click Save. Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 16: Hardware

    Check Motion Detection Enabled. Make any adjustments to sensitivity settings. Click Save. Select Buttons. Disable Quick Dial Buttons by clicking the x. 4. Click Save. 10. Click Save. Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 17: Blueprint Configuration

    6. Blueprint Configuration To integrate a 2N door station to a Savant system, a blueprint configuration must be configured and uploaded to the host. In an open Blueprint configuration, do the following: Click Show Library. 10. Click Done. In the Search bar type 2N.
  • Page 18: Entry Service Screen Buttons

    6.1. Entry Service Screen Buttons Custom buttons can be added to the Entry Service Screen in the Savant Pro App. This section describes how to create a button that open or close a 2N Door Station Switch via a press of a custom Entry Service Screen button.
  • Page 19 A boolean state that the system will track the to determine if the Command or Toggle Command is sent. Follow Inverse of State Inverts when the button will use the Command and the Toggle Command. Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 20: Audio Interrupt Service (Ais)

    4. Click the plus sign to create a new trigger. The image below shows an example: When Any Of These States Change Value... EntryRing If (Rules) EntryRing is True Then AutoStartAIS Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 21: Remote Calling

    Motion is Detected Tampering Detection must be enabled in Blueprint to receive Noise is Detected these notifications. Tampering is Detected CANCEL NEXT Tap Next. Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 22: System Monitor

    This list displays the name of the device connected to the extensions. Device and connection information. Device Status See the Device Status for more information. Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 23 Current state of Relay 1. Relay 2: Current state of Relay 2. Output 1: Current state of Output 1. Output 2: Current state of Output 2. Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 24: Appendix A: Switch Configuration

    Appendix A: Switch Configuration A Switch must be configured within the webUI if a 2N door station is used to control a relay or GPIO within the Savant configuration. This example uses the output of the door station to supply voltage to a 3rd party door lock.
  • Page 25 Code NOTE: Requires IP Verso with touch display/keypad or IP Force. For more information on switch features, see the 2N IP Configuration Manual. Entry Service with 2N Door Stations Deployment Guide Copyright © 2020 Savant Systems, LLC 009-1540-01 | 200204...
  • Page 26: Appendix B: Door Lock Service

    Click the + Plus icon. Select the door station as the controller. 4. Select the location the Door Lock service will populate in on the Savant Pro App. Select Entity type. Enter the Switch address in the Door Lock Address field.
  • Page 27: Appendix C: External Camera Feeds

    Appendix C: External Camera Feeds To use an external camera for the feed shown in the Savant Pro App and TrueControl II for the Entry and Camera service for the door station, the 2N web interface must be configured. Once connected to the door station via the web interface: Check the External Camera Enabled check box.
  • Page 28: Appendix D: Static Ip Address

    Appendix D: Static IP Address Savant recommends using DHCP reservation. If a static IP Address is required, it must be set in the door station web UI. Within the 2N door station web UI, follow the steps below: Uncheck Use DHCP Server.
  • Page 29 Savant Systems, LLC. shall not be liable for any technical or editorial errors or omissions contained herein or for incidental or consequential damages resulting from the performance, furnishing, reliance on, or use of this material.

Table of Contents

Save PDF