INSTRUCTIONS FOR THE INSTALLER
Adjacent walls, cupboards and protection for
combustible materials.
Ensure that the appliance is installed in
accordance with clauses 6.2.5 and 6.10.1.1 of AS/
NZS 5601.1, or clauses 6.9.1 and 6.9.5 of
AS/NZS 5601.2 with regard to clearances
to combustible surfaces and materials, and
clearances to rangehoods and exhaust fans.
Clearance of 200mm from the periphery of burners
to vertical combustible surfaces is required.
Clearances to combustible surfaces may be
reduced only if combustible surfaces are protected
in accordance with clause 6.10.1.2 of AS/NZS
5601.1, or clause 6.9.2 of AS/NZS 5601.2.
The equipment must not be installed near
inflammable materials, such as curtains,
cloths,etc. Make a cut out in the benchtop, with
the dimensions indicated in fig.3, at a distance of
at least 50 mm from the appliance border to the
adjacent walls.
MODEL
L (mm)
HG60FXA
HG75FXB
HG90FXB
HG90FX-MB
Rangehoods and exhaust fans* shall be installed
in accordance with the manufacturer's relevant
instructions. However, in no case shall the
clearance between the highest part of the hob
of the gas cooking appliance and a range hood
be less than 650mm or, for an overhead exhaust
fan, 750mm. (*An exhaust fan is defined as a
mechanical device other than a rangehood for
moving air from one interior space to another, or
to outside of the space)
IMPORTANT:
A separation panel at least 10mm from the
bottom of the cooktop must be included during
installation to prevent access to the underside
of the appliance. This panel can be made of any
non-combustible rigid material. Refer (fig. 4).
If the hob is going to be installed on the top of an
oven, precautions must be taken to guarantee an
installation in accordance with current accident
prevention standards. Pay particular attention to
the position of the electric cable and gas pipe: they
must not touch any hot parts of the oven.
Moreover, if the hob is going to be installed on
the top of a built in oven without forced cooling
ventilation, proper air vents must be installed to
guarantee an adequate ventilation, with the lower
P (mm)
D (mm)
560
480
720
480
860
480
air entering with a cross section of at least 200cm
and the higher air exiting with a cross section of at
least 60 cm
Fastening the top
Every cook-top is equipped with a special washer.
A set of hooks is also supplied for mounting the
cook-top.
Depending on the type of mounting surface, the
suitable type of mounting hook is supplied (hook A
or hook B).
For the installation proceed as follows:
– Remove all loose components from the top.
– Turn the appliance upside down lay it's edges on
foam packaging blocks to prevent damage to the
ignition spark plugs and lay the seal S along the
external border (fig. 5).
– Introduce and place the cook-top in the hole
made in the piece of furniture, then fasten it
with the screws and fastening brackets supplied
(fig.6).
WARNING: Failure to fix the cooktop to the bench
could result in loosening of the gas connection
60
through movement of the cooktop and a gas leak
may result.
60
A duplicate rating label is included with these
instructions. Ensure this is attached to a readily
60
accessible surface, so that the cooktop can be
easily identified in the case of a service call.

INSTALLATION ROOM

This appliance is not provided with a device for
exhausting the products of combustion.
Therefore, it is necessary to discharge these
outside.
The room where this appliance is installed
must have a natural air inflow, so as to ensure
a regular gas combustion and room ventilation:
the necessary air volume must not be lower than
20m
.
3
Air must come from permanent openings made on
the room walls that communicate with the outside.
The section of these openings shall correspond to
at least 200 cm
OPERATION ON N.G / S.N.G.
Regulator
An appliance regulator is provided. The regulator
must be positioned so that the pressure test nipple
is accessible when the appliance is installed.
Connect the gas supply to the 1/2" B.S.P. internal
thread inlet of the regulator. Refer to page 8 for
connection point position.
Regulators are supplied pre-adjusted and
configured by the component maker for use with