7.2 Frequency Drive Settings

7.2a Standard Drive Parameters
There are two drives that control the case transport roller conveyors.
recommended drive settings. Only settings that vary from drive default settings are shown.
For specific information regarding programming of the PowerFlex4M frequency drive refer
to the manufactures' operation manual, www.rockwellautomation.com / Publication 22F-
UM001C-EN-E
Drive 1 [Scale Conveyor]
No.
Parameter
P101
Motor NP Volts
P102
Motor NP Hertz
P103
Overload
P105
Maximum Frequency
P106
Start Source 1
P108
Speed Reference 1
P109
Acceleration Time
P110
Deceleration Time
A410
Preset Frequency 0
A451
Auto Restart Tries
A452
Auto Restart Delay
Drive 2 [Outfeed Case Transport]
No.
Parameter
P101
Motor NP Volts
P102
Motor NP Hertz
P103
Overload
P105
Maximum Frequency
P106
Start Source 1
P108
Speed Reference 1
P109
Acceleration Time
P110
Deceleration Time
A410
Preset Frequency 0
A451
Auto Restart Tries
A452
Auto Restart Delay
31
See tables below for
Parameter Value
Default
Set
480
380
60
50
0.9
0.9
60
80
1
2
1
4
10
0.5
10
0.5
0
50
0
9
1
0
Parameter Value
Default
Set
480
380
60
50
0.9
0.9
60
80
1
2
1
4
10
0.5
10
0.5
0
50
0
9
1
0