CW-1RC SERIES CHECKWEIGHER
{MESSAGE DISPLAY BOX} (Located on Bottom of Screen)
The message display box will display various status messages based on normal machine
operation. Refer to Figure 6.1.2 Message Display Information below for a list of the
messages that may be displayed and a description of why.
Message
Safety Circuit Activated
Please Wait...Machine
Powering Up
Machine Ready
Machine Running
Cycle Stop Initiated
Machine Holding – Outfeed
Blocked
Clear Cases Before Starting
Machine in Alarm
Displays when an e-stop has been pressed or a guard door has
been opened and the machine hasn't not been reset
Displays after the reset pushbutton has been pressed. During
this time the drives power-up and the main air to come up to full
pressure
Displays after the power-up period and after cycle stopping as
long as fill station is clear and customer has given permission to
run. Pressing "START" will start the machine
Is displayed after the machine has been started and during
normal machine production
Is displayed after the user presses "STOP" button during
production.
Is displayed when the "outfeed blocked" photoeye is blocked.
No cases will be release from the machine until the photoeye is
cleared.
Is displayed if case is blocking "case in checkweigh" position
photoeye when machine is reset, but not started. Machine
cannot be started if case is on scale and requires operator to
remove the before starting.
An alarm was generated during production and the machine is
automatically cycle stopped.
Figure 6.1.2 – Message Display Information