FUXTEC FX-MSP2.2 Original User Manual
Hide thumbs Also See for FX-MSP2.2:

Advertisement

Original User Manual FUXTEC FX-MSP2.2_rev08
O
Original User Manual
FUXTEC Motor Sprayer Model FX-MSP2.2
Fig. similar
FUXTEC GmbH
Kappstrasse 69, 71083 Herrenberg-Gülstein, Germany
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FX-MSP2.2 and is the answer not in the manual?

Questions and answers

Summary of Contents for FUXTEC FX-MSP2.2

  • Page 1 Original User Manual FUXTEC FX-MSP2.2_rev08 Original User Manual FUXTEC Motor Sprayer Model FX-MSP2.2 Fig. similar FUXTEC GmbH Kappstrasse 69, 71083 Herrenberg-Gülstein, Germany...
  • Page 2: Table Of Contents

    Original User Manual FUXTEC FX-MSP2.2 Table of contents Introduction....................3 Safety and Warning Instructions ..............4 Commissioning of the device ............... 7 Filling and starting ..................10 Nebulizing / Fogging ................. 14 Malfunctions and troubleshooting ............... 15 Technical maintenance and storage ............17 Technical execution ..................
  • Page 3: Introduction

    Original User Manual FUXTEC FX-MSP2.2 Introduction The FUXTEC FX-MSP2.2 motorized sprayer is portable, flexible, and made of high- quality / high-performance material for weed control and protection of plants in large areas and the protection of crops. The device can also be used to remove weeds, leaves and fertilizers, and salt spraying.
  • Page 4: Safety And Warning Instructions

    Original User Manual FUXTEC FX-MSP2.2 Safety and Warning Instructions 1. Read the instructions carefully. Be sure that you have understood the operating instructions precisely before you start working with the device. 2. Wear safety clothing / protective clothing such as:...
  • Page 5 Original User Manual FUXTEC FX-MSP2.2 5. Starting the device 1) Switch the dust nozzle to the lowest position before starting the device. Otherwise, the chemical will be sprayed when you start the engine. 2) It is forbidden to stand at the front of the blow nozzle. Even if the spray nozzle is closed, residues of the residual dust may be deposited on the tube.
  • Page 6 Original User Manual FUXTEC FX-MSP2.2 Please wear a respirator and eye protection mask during work! Please wear protective gloves during work! Please wear a protective suit during work! Please wear safety shoes during work! WARNING: Spray materials must not be inhaled under any circumstances! WARNING: highly flammable petrol mixture;...
  • Page 7: Commissioning Of The Device

    Original User Manual FUXTEC FX-MSP2.2 Commissioning of the device 1. Change from liquid to granulate sprayer (e.g., salt) Remove the side safety nuts (1) of the chemical tank and disassemble the tank (see next step in fig.2. Remove the spray insert and insert the granule insert (2, Fig.1).
  • Page 8 Original User Manual FUXTEC FX-MSP2.2 Fig. 3 1.Sealing 2.Connection 3.Fixing screw 3)Connect the spray unit to the device as shown in Fig. 4 2. Assembly of the spray nozzle Fig. 5 1. Flexible hose 2. Spray pipe 3. Handle/gas handle 4.
  • Page 9 Original User Manual FUXTEC FX-MSP2.2 3. Anti- Electrostatic Installation Dusting or spreading of the chemical granules can generate electrostatic charges. This is proven after the application of such chemicals under certain conditions of air temperature and humidity. Please use the enclosed safety chain (C) to avoid electrostatic charges and mount the cable lug (A) on the pull starter.
  • Page 10: Filling And Starting

    Original User Manual FUXTEC FX-MSP2.2 Filling and starting 1.Testing before commissioning 1) Check if the spark plug etc. is loose. 2) Check if the air cooling opening is blocked to prevent overheating. 3) Check if the air filter is dirty.
  • Page 11 Original User Manual FUXTEC FX-MSP2.2 4. Cold start Please follow the instructions before operating the device: 1) move the fuel lever to the start position (Fig. 9). 2) Pull the choke lever to the ON position. 3) Slide the start/stop switch to the start position.
  • Page 12 Original User Manual FUXTEC FX-MSP2.2_rev08 Fig. 9 Petrol tap 1. Choke lever 2. Petrol tap Pos. A: OPEN Pos. B: CLOSE 3. Air Filter 4. Primary pump 5. Warm start 1) Leave the choke in the OFF position. 2) Set the fuel lever to the ON position.
  • Page 13 Original User Manual FUXTEC FX-MSP2.2 Switching off the device 1) During operation, first switch off the chemical spray function and then stop the device by moving the start/stop switch to the Stop position. 2) During the dusting function, push the fuel and dusting lever to the closed position.
  • Page 14: Nebulizing / Fogging

    Original User Manual FUXTEC FX-MSP2.2 Nebulizing / Fogging 1) Spray: Open the spray cover and adjust the spray nozzle's length to obtain the required quantity. Use the control to change the amount of atomization. Fig. 11 Fig. 11 Opening Filling (L/min) 2) Fogging: Adjust the removal dosage during the spraying process on the boom (see Fig.
  • Page 15: Malfunctions And Troubleshooting

    Original User Manual FUXTEC FX-MSP2.2 Malfunctions and troubleshooting The device starts badly or cannot be started at all: Check whether the spark plug generates a spark. Unscrew the spark plug. Insert the spark plug back into the spark plug connector and ensure that the spark plug is grounded.
  • Page 16 Have it cleaned or replaced Accessible screws Tightening and nuts (not set screws) Security stickers Replace 1) Please contact the service department of FUXTEC GmbH 2) Screw-in the carburettor screw completely, then turn it back on 1.5 turns.
  • Page 17: Technical Maintenance And Storage

    Original User Manual FUXTEC FX-MSP2.2 Technical maintenance and storage 1. Technical supervision of the spray components 1) After spraying, clean all residues of the mixture from the chemical tank. Wash the tank and all other parts. 2) After spraying or granule distribution, clean the spray extension and chemical tank inside and outside.
  • Page 18 Original User Manual FUXTEC FX-MSP2.2 2) Remove the spark plug. Pour 15-20g of engine oil into the cylinder; the engine oil should be a 2-stroke oil for gasoline engines. Then screw the spark plug back 3) Unscrew the two wing screws. Remove the tank from the device. Clean the atomizer and the surface inside and outside the chemical tank.
  • Page 19: Technical Execution

    Original User Manual FUXTEC FX-MSP2.2 Technical execution Model FX-MSP2.2 General dimensions (mm) 420×500×800 Net weight (kg) 11.5 Chemical tank capacity (L) Spray mixture (L/min) ≥4 Delivery Dimensions of the chemicals Fog mixture (kg/min) ≥6 Range (m) ≥11 Quantity of fuel mixture between...
  • Page 20: Ec Declaration Of Conformity

    Original User Manual FUXTEC FX-MSP2.2 EC Declaration of Conformity according to the directive 2006/42/EC and the addendum 2009/127/EC FUXTEC GmbH Kappstrasse 69, 71083 Herrenberg - Germany declares in sole responsibility that the product Model: Motor Sprayer FX-MSP2.2 to which this declaration refers, fully complies with the relevant essential health and safety requirements of Directives 2006/42/EC with the supplementary addendum 2009/127/EC and the needs of the other applicable directives.