General Technical
Charger ADP-50ER
Specifications
Input Voltage Range
100-240 V AC
Output Voltage
24.8 V DC (25.2 V DC fully charged)
Output Current
2.0 A
Casing Dimensions
135 x 62 x 34 mm
DC Cable Length
1.80 m
Weight
400 g
Working Temperature
- 5 °C to + 40 °C
Casing Material
Plastic
4
NAO Charger 20190516.indd 4
Power Connector Socket
Battery Charger Casing
LED
Battery Charger Cable
Battery Charger Connector
Power Cable
Power Connector
Plug
Charger ADP-50MR
155 x 67 x 37 mm
500 g
CHARGING NAO
• Insert the plug into the wall socket (1).
• Insert the Connector into the Robot (2).

OPERATION

The Battery Charger may become warm when charging. Please refer to the
following table concerning the LEDs functioning.
LED Color
ADP-50ER Charger
Charger not connected to
Solid green
the Robot or Battery fully
charged.
Flashing
-
green
Solid red
Battery is charging.
PROTECTION AND RESET
When the LED is off but the Charger is connected, the following protections
may have triggered:
Overvoltage
Shortcircuit
Overcurrent
Reverse Voltage
Temperature
1
2
ADP-50MR Charger
Battery is fully charged.
Charger not connected to the
Robot.
To reset the Charger, disconnect from
the wall socket and reconnect.
To reset the Charger, disconnect from
the wall socket and reconnect. War-
ning! The Charger may be permanently
damaged.
Unplug the Charger and wait until tem-
perature decreases below +40°C. To
reset the Charger, unplug and replug
the wall socket.