1. INTRODUCTION
The new NIVOROTA E-700/800 rotary paddle level switches of the well-known NIVELCO design can be
used for detecting the level of lumpy materials, powders, and granules. Mounted onto tanks, silos, and
hoppers, they monitor and control the level, filling, and emptying of stored materials such as stones, fly ash,
sand, coal, feed, beet slices, etc.
A low-power electric motor drives the paddle, which rotates freely in the absence of the material. Its rotation
in the EK/H is mono-directional; in the EL/M, it is bidirectional. When the medium reaches the paddle, the
output contact switches from NC state to NO state, and the motor is turned off. When the material level
drops, the paddle runs free again, the motor is reactivated, and the switch returns to its original state (NC).
In the case of low-level detection, the material usually covers the blade, with the output contact staying in NO
state, and the motor stopped. When the material drops to a level where the paddle can rotate freely again,
the motor restarts and the control switch returns to the NC position.
The process connection can be threaded (1" or 1½" BSPT) or a mounting plate. It is recommended to use
adapters for threaded connection points other than the standard version. The mounting plate can be attached
to the unit with a threaded process connection. Mounting nuts are available for mounting onto a bracket,
depending on the size of the process connection. A suitable paddle must be chosen for every particular
medium density. The single-blade paddle is recommended for higher density materials and granular solids,
while the 3-blade paddle is recommended for lower density materials, powders, and solids. The 1-blade or
2-blade paddle can also be used with a suitable threaded connection, while the 3-blade paddles can only be
installed using a mounting plate.
If the standard version's insertion length is not enough, there are rod or cable extension types available,
depending on the application. For light materials with moderate stress, the solution is to use Ø10 pipe
extension. The device's shaft must be protected against being hit by falling stones or other coarse materials
by using a flexible coupling. If the insertion length is customized for any technical reason, the rod-extended
design with an adjusting unit is recommended. This can be ordered separately. In the case of a cable
version, if the desired length falls between two available sizes, the desired length can be achieved by cutting
the cable to the appropriate size. The counterweight stretches the cable to avoid the paddle climbing up onto
the medium surface. If additional stiffening of the cable probe is required, a rigid pipe can be ordered as an
accessory. Caution! If the pipe is cut to size, at least 30 mm (1.2 inches) must be left free between its top end
and the cable rope assembly connector.
If the medium temperature exceeds 120 °C (248 °F), a high-temperature version must be used, equipped
with a heat sink, raised from the process connection, and only available with aluminum housing. Dust-Ex
versions are available for use in hazardous environments.
2. TECHNICAL DATA
2.1 G
ENERAL DATA
Version
EL / EK – 7
Standard: 200 mm (7.85 inches) – Rod extension: 0.4 – 3 m (1.3 – 10 ft)
Insertion length (L)
Number and material of
the blades
Rotation speed
Material of wetted parts
1.4571 (316Ti) Stainless Steel, Material of the seal: NBR
Medium density
(guideline value)
-20 °C ...+120 °C
(-4 °F ...+248 °F)
Medium temperature
Ambient temperature
Relative humidity
Process pressure
Output
Paddle-rotation /
shutdown indication
Nominal value: 230 VAC (50/60 Hz) +10% -15%, 120 VAC (50/60 Hz) +10% -15%
Power supply
Process connection
Power consumption
2x M20x1.5 plastic cable glands, for 6 – 12 mm (0.25 – 0.5 inches) cable + Two internally
Electrical connection
threaded ½" NPT connection for protective pipes 2x terminal blocks for 0.5 – 1.5 mm
Electrical protection
Ingress protection
Housing material
Powder-coated aluminum
Standard: 1.6 kg (3.52 lb), Rod-extended: 1.6 kg (3.52 lb) + extension 1.6 kg/m (1 lb/ft),
Weight
Cable-extended: 2.6 kg (5.73 lb) + extension 1.4 kg/m (0.94 lb/ft), counterweight: 1 kg (2.2 lb)
* Types EK / EH--4M,-8M use 24 VDC (-15%...+10%)
The connection between the device housing and the process connection is rigid, it cannot be turned or twisted
Standard
EL / EK – 8
Cable extension: 1 m – 3 m (3.3 – 10 ft)
1.4571 (316Ti) / 1, 2, 3; as per order code
~1 rpm (@50 Hz)
min. 0.1 kg/dm
3
-20 °C ...+80 °C
(-4 °F ...+176 °F)
Ex variant: see Special data for Ex certified models
-30 °C ... +60 °C (-22 °F ... +140 °F)
max. 90%
max. 3 bar (0.3 MPa, 43.5 psig)
SPDT 250 VAC, 6A, AC1
Two-toned (green/red) LED
24 VAC (50/60 Hz) +10 % -15%, 24 VDC (18–28 VDC)*
1" BSPT; 1½" BSPT; mounting plate
(BSPT thread can also be screwed into BSP or NPT thread)
max. 4 VA (4 W)
(AWG20 – AWG15) wire cross section
Class I
IP67
Plastic (PBT)
High-temperature
EM / EH – 7
2.2 E
Electrical
connection
Ex marking
1.4571 (316Ti) Stainless
Steel, Material of the seal:
T
EMPERATURE DATA FOR
FPM
-20 °C ...+200 °C
(-4 °F ...+392 °F)
T85°C
T100°C
T135°C
T200°C
2.3 A
2
Powder-coated aluminum
S
E
X
PECIAL DATA FOR
X CERTIFIED MODELS
2x M20x1.5 metal cable glands, cable outer
diameter: 8 – 13 mm (0.31 – 0.51 inches)
II 1/2 D Ex tb IIIC IP67
E
X VERSIONS
Type
Standard type
High-temperature type
85
30 min
85
°C
°C
60
°C
100
20 min
100
°C
°C
120
50
5 min
120
°C
°C
°C
-
200
°C
CCESSORIES
User's manual
Warranty Card
EU Declaration of Conformity
1-, 2- or 3-blade paddle (as per order
code), 2 pcs. split pin
eka7021a0600h_06
30 min
20 min
60
°C
5 min
0 min
1 / 5

Advertisement

loading

Summary of Contents for NIVELCO NIVOROTA EL 7 Series

  • Page 1 We are convinced that you will be satisfied with our product. 1. INTRODUCTION The new NIVOROTA E-700/800 rotary paddle level switches of the well-known NIVELCO design can be used for detecting the level of lumpy materials, powders, and granules. Mounted onto tanks, silos, and hoppers, they monitor and control the level, filling, and emptying of stored materials such as stones, fly ash, sand, coal, feed, beet slices, etc.
  • Page 2: Order Code

    2.4 O RDER – – Probe version / Paddle / Version Code Code Housing Code Code Insertion length Code Power supply / Certificate Code Process connection Standard Aluminium 230 VAC Standard / Single-blade High-temperature paddle / 1" BSPT Plastic 0.1 m 120 VAC (2) (3) 0.2 m...
  • Page 3 2.5.2 A CCESSORIES Single-blade curved paddle 2-blade flexible paddle Single-blade 90° paddle (168 mm, 6.6 inches) (172 mm, 6.8 inches) (130 mm, 5.1 inches) EAL–701–1 EAL–703–1 EAL–707–1  Can be inserted even through a  Inserted through a 1",  Inserted through a 1½", 50 mm 1", 90 mm (3.5 inches) long 45 mm (1.75 inches) (2 inches) long process...
  • Page 4: Installation

    3. INSTALLATION The device can be installed in several ways, depending on the design (vertical, horizontal, angle), with threaded connections, mounting plates, adapters, adjusting units, etc. The unit must be protected against steady material influx by selecting the appropriate mounting position or using an overhead protective shield. When the device is mounted onto the side of the tank, coning or arching of the material must be taken into consideration.
  • Page 5: Maintenance & Repair

    January 2021 6. OPERATION NIVELCO reserves the right to change technical specifications The device must be connected to the protective earth with its internal or external without notice. grounding screw! After energizing the supply terminals, the unit is fully operational.

This manual is also suitable for:

Nivorota ek 7 seriesNivorota el 8 seriesNivorota ek 8 seriesNivorota em 7 seriesNivorota eh 7 series