Kenwood TK-3207G Service Manual page 45

Uhf fm transceiver
Table of Contents

Advertisement

TK-3207G
Item
Condition
1.BPF Wave
(1)Center frequency
Adjust
Spectrum analyzer setting analyzer
TK-3207
Center-f : 360MHz
(C6)
Span : 100MHz
RBW : 300kHz
VBW : 10kHz
ATT
(2)High-edge frequency
Spectrum analyzer setting
Center-f : 370MHz
(3)Low-edge frequency
Spectrum analyzer setting
Center-f : 350MHz
2.Sensitivity
TEST CH: Low
Check
[Wide]
SSG output:–117 dBm(0.3µV) AF VTVM
SSG MOD:3.0kHz
[Narrow]
TEST CH:Center
SSG output:–115 dBm(0.4µV)
SSG MOD:1.5kHz
3.SQL1
TEST CH: Center
(Threshold)
Writing
[Wide]
SSG output:–123 dBm(0.16µV)
SSG MOD:3.0kHz
[Narrow]
TEST CH: Center
SSG output:–122 dBm(0.18µV)
SSG MOD:1.5kHz
4.SQL9
TEST CH: Center
(Tight)
Writing
[Wide]
SSG output:–117 dBm(0.3µV)
SSG MOD:3.0kHz
[Narrow]
TEST CH: Center
SSG output:
–116 dBm(0.35µV) (C, C2)
–117 dBm(0.3µV) (C5, C6)
SSG MOD:1.5kHz
5.BATT
BATT terminal voltage:5.9V
detection
Writing
44
ADJUSTMENT /
Measurement
Test equipment
Spectrum
: 10dB
SSG
Center
DVM
High
Oscilloscope
Low
High
Low
High
DVM
调整
Adjustment
Terminal
Parts
ANT
Programming
BPF
Software:
KPG-87D
ANT
Programming
Software:
KPG-87D
ANT
BATT terminal
Specifications/
Remark
Method
Adjust the
MKR 360.0 MHz
REF -38.0 dBm
5dB/
A_View
Norm
B_Blank
Norm
waveform as
shown to the
right.
CENTER 360.0 MHz
*
RBW 300 kHz
*
VBW 10 kHz
SWP 70 ms
MKR 370.0 MHz
REF -38.0 dBm
5dB/
A_View
Norm
B_Blank
Norm
CENTER 370 MHz
*
RBW 300 kHz
*
VBW 10 kHz
SWP 70 ms
REF -38.0 dBm
MKR 350.0 MHz
5dB/
A_View
Norm
B_Blank
Norm
CENTER 350.0 MHz
*
RBW 300 kHz
*
VBW 10 kHz
SWP 70 ms
Check
12dB SINAD or more
Write
Squelch open
Write
BATT terminal
voltage:5.9V
-46.617 dBm
SPAN 100.0 MHz
*
ATT 10dB
-46.617 dBm
SPAN 100.0 MHz
*
ATT 10dB
-46.906 dBm
SPAN 100.0 MHz
*
ATT 10dB