Condition
Panel tuning
mode
[Analog
1) Adj item:
Wide 4k]
[As TONE]
Adjust:[****]
2) Adj item:
[L1]→
[L3]→
[L5]→
[C1]→
[C3 TxOL:L]→
[C5]→
[H2]→
[H4]→
[H6]→
[C3 TxOL:H
(Long press the
[] button)]
Adjust:[****]
PTT : ON
Press [
]
button to store
the adjustment
value.
[Analog
1) Adj item:
Narrow]
[An TONE]
Adjust:[****]
2) Adj item:
[L1]→
[L3]→
[L5]→
[C1]→
[C3 TxOL:L]→
[C5]→
[H2]→
[H4]→
[H6]→
[C3 TxOL:H
(Long press the
[] button)]
Adjust:[****]
PTT : ON
Press [
]
button to store
the adjustment
value.
Measurement
PC test mode
Test-
equipment
1) Adj item:
Deviation
[Single Tone
meter
Deviation (Analog
Oscilloscope
Wide 4k)]
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]→
[Overlap]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
1) Adj item:
Deviation
[Single Tone
meter
Deviation (Analog
Oscilloscope
Narrow)]
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]→
[Overlap]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Unit Terminal Unit
Parts
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[+], [-]
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[+], [-]
Adjustment
Specifications
Method
Write the fixed value
2.40kHz±0.05
"520" for each
kHz
adjustment points.
Write the fixed value
1.50kHz±0.05
"520" for each
kHz
adjustment points.
(No.RA058<Rev.001>)1-143