1. After each use, unplug the power cord and leave the device to cool down.
2. Remove the lid and the trays for sterilizing/ heating.
3. Pour out the residual water in any of the compartments – for sterilizing or warming baby bottles.
4. Wipe the device inside and outside with wet cloth.
5. Do not use strong detergents for cleaning the unit – bleach, alcohol based ones (wet antibacterial wipes) or
such with abrasive parts.
6. We recommend you to use pre-boiled or filtered water in the device in order to reduce the risk of lime
scale deposition.
Note: After cleaning the product, storage it in a clean, dry place away from the reach of children.
B. DESCALING THE BASE OF THE STERILIZING COMPARTMENT:
1. Pour 50ml (1.07оz) of white vinegar and 100ml (3.40 оz) of cold water into the reservoir in the base of the
sterilizing compartment. Plug in the supply cord of the device. Choose mode sterilization and adjust the time to 5
minutes. Leave the device to work until it is completely cleaned from the lime scale dissolves.
2.Unplug the power cord.
3.Leave the device to cool down. After that pout out the rest of the residual solution and wipe the inside the
compartment in order to remove if anything is left.
4.If the limescale has not cleaned completely, repeat the procedure again.
5.DO NOT put the device into dishwasher!
C. DESCALING THE BASE OF THE HEATING COMPARTMENT:
1. Pour 30ml of white vinegar and 50ml of cold water into the reservoir in the base of the baby bottle warmer
compartment. Plug in the supply cord of the device. Choose mode fast warming and adjust the time to 5 minutes.
Leave the device to work until it is completely cleaned from the lime scale dissolves.
2.Unplug the power cord.
3.Leave the device to cool down. After that pout out the rest of the residual solution and wipe the inside the
compartment in order to remove if anything is left.
4.If the limescale has not cleaned completely, repeat the procedure again.
5.DO NOT put the device into dishwasher!
D. Maintenance guide:
• Check regularly the main parts of the device and the power cord for any damages, broken or missing parts. If
you find such, contact the shop, from which you bought the product for advice.
• If there is damage, do not try to repair the product by yourselves. Otherwise, your guarantee will not be active
anymore.
Question
The device will not switch on
Reduced effectiveness when
heating/ works but it does not heat
up
White spots on the water reservoir,
the sterilizing body, the tray or the lid
Alarming sounds

TROUBLESHOOTING

•If any of the above does not lead to any result, contact the shop, from
Check if there is scale on the heating plates. Descale as described in
this manual and as many as times it is needed to completely clean the
device from the limescale and it to start working normally. Clean the
Deposition of lime scale is normal and it happens faster in the areas with
more hard water. Clean the device regularly from the lime scale.
•Check if the heating/ sterilizing process hasn't finished.
Manufactured for CANGAROO
Importer: Moni Trade LTD
Address: Bulgaria, Sofia, quarter Trebich, Dolo str. 1
Tel.: +359 2/ 936 07 90
Answer
•Check if the power cord in plugged in.
•Check if the mains socket outlet has electricity.
•Check if the fuse has not tripped off.
which you bought the product.
device from limescale at least twice a week.
•Check if there is water in the compartment.