B&K Reference 30 Owner's Manual page 68

A/v system controller
Table of Contents

Advertisement

From Remote
­
V
1
(PAUSE) or
(STOP)
2
SEL or ENTER
Zone 2 (B) Level Control - You may wish to install an in-wall volume control in your second zone. This can cause
confusion between your processor's internal Zone 2 (B) volume controls and your in-wall controls.
WARNING - Setting Zone 2 (B) LEVEL CONTROL to FIXED will cause your processor to immediately send
its maximum Zone 2 (B) volume to your second zone (if Zone 2 (B) is on). Turn down your in-wall volume
controls before making this change.
ADVANCED ZONE B SETTINGS
1 Level Control
1 Level Control
2 Fixed Level
3 Zone ID
4 V2 Output
5 Link Input to Zone A
6 Link Power to Zone A
From Remote
­
V
1
(PAUSE) or
(STOP)
ˆ
‡
2
(REW) or
(FF)
Zone 2 (B) Max (Fixed or Variable) Level - Z2 max level allows you to set a maximum volume level for Zone 2
(B). This is very useful if you are using speakers that can't handle the maximum power output from your external
amplifier or if you simply wish to limit the volume that can be achieved using normal front panel or remote
operation. If you have chosen Zone 2 (B) level control (fixed), then this setting becomes the fixed level for Zone 2
(B). If you have chosen Zone 2 (B) level control (variable) then this setting allows the level for Zone 2 (B) to be
adjusted. However, when adjusting this level it cannot exceed the value set in Zone 2 (B) max level.
WARNING - If you set this level too low, the processor may appear broken (no sound).
ADVANCED ZONE B SETTINGS
1 Level Control
2 Fixed Level
2 Fixed Level
3 Zone ID
4 V2 Output
5 Link Input to Zone A
6 Link Power to Zone A
From Remote
­
V
1
(PAUSE) or
(STOP)
ˆ
‡
2
(REW) or
(FF)
From Front Panel
(UP) or
(DOWN)
(ENTER)
Variable
Variable
+15 dB
2
Tape
No
No
next item
adjust
MENU advanced setup
From Front Panel
(UP) or
(DOWN)
VOLUME KNOB
Variable
+15 dB
+15 dB
2
Tape
No
No
next item
adjust
MENU advanced setup
From Front Panel
(UP) or
(DOWN)
VOLUME KNOB
Action
move to Zone 2 Setup (B)
activate ADVANCED ZONE B SETTINGS
ADVANCED ZONE B SETTINGS
1 Level Control
1 Level Control
2 Fixed Level
3 Zone ID
4 V2 Output
5 Link Input to Zone A
6 Link Power to Zone A
next item
MENU advanced setup
Action
move to Level Control
adjust level to desired value
ADVANCED ZONE B SETTINGS
1 Level Control
2 Fixed Level
2 Fixed Level
3 Zone ID
4 V2 Output
5 Link Input to Zone A
6 Link Power to Zone A
next item
MENU advanced setup
Action
move to Fixed Level
adjust level to desired value
65
Fixed
Fixed
+15 dB
2
Tape
No
No
adjust
Fixed
+15 dB
+15 dB
2
Tape
No
No
adjust
p/n 12857 Rev. 0717A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents