The unit has two different volume flow or air flow rates as standard. When the Silent Mode button is pressed (the
green button lights up), the unit air flow will reduce (Fig.11). When Silent Mode is activated, the power and unit air flow
will reduce and thus enable quieter operation.
When the Silent Mode button is pressed again, this mode will end and the unit will return to normal operation.
Fig�11
the required air flow or the necessary air exchange is not achieved in Silent Mode, this mode should only be
If
active for a short period�
AirPal 1200 U
Setting
Flow rate /
air volume
(m³/h)
Silent Mode
900
Normal
1200
4�2 LED indicators
Fig�12
AirPal 900 U and 1200 U indicators
Indicator position
Blue light on (Power)
Yellow light on (ePM1)
Yellow light on (ePM10)
Yellow light on (UVC
lamp)
Silent Mode Button/
green light
Sound pres-
Power (W)
sure at 1 m
(dBA)
40
440
45
480
Status
Action
Unit is running
-
ePM1 80% filter is dirty
Change ePM1 filter
ePM10 70% filter is dirty
Change ePM10 filter
The end of the UVC lamp
The UVC lamps should be replaced becau-
service life is reached
se they are no longer achieving the required
radiation capacity.
Silent mode activated
-
9
AirPal 900 U
Flow rate / air
Sound pres-
volume (m³/h)
sure at 1 m
(dBA)
600
40
900
45
Power
(W)
340
380