Emergency Stop Safety Relay SR7C
User Information
The SR7C is a universal emergency stop safety switching device
Correct Use
with seven safe relay outputs that can quickly and safely stop the
moving parts of a machine or system in case of danger.
Applications for the SR7C include single or dual-channel emer-
gency stop circuits and guard monitoring on machines and sys-
tems.
Features
7 safe, redundant relay outputs
4 auxiliary relay and 2 auxiliary semiconductor outputs
Connection of:
- Emergency stop buttons
- Safety switches
- Non-contact safety switches
- OSSD-Outputs
Single or dual-channel operation possible
Feedback loop for monitoring downstream contactors or
expansion modules
Cyclical monitoring of the output contacts
Indication of the swiching state via LED
Function
The emergency stop safety switching device SR7C is
designed for safe isolation of safety circuits according to
EN 60204-1 and can be used up to safety category 4, PL e
according to EN ISO 13849-1.
The internal logical system closes the safety contacts when
the start button is pressed.
If the safety switch is opened, the positively driven safety
contacts are opened and safely switch the machine off. It is
ensured that a single fault does not lead to a loss of the
safety function and that every fault is detected by cyclical
self-monitoring no later than when the system is switched
off and switched on again.
The operating status of the device is indicate by the auxilia-
ry transistor outputs O1 and O2.
O1: Ready. PWR is connected.
O2: Both relay channel K1, K2 are switched on.
Installation
As per EN 60204-1, the device is intended for installation in
control cabinets with a minimum degree of protection of
IP54. It is mounted on a 35 mm DIN rail according to
DIN EN 60715 TH35.
Installation and commissioning of the device must be
Safety
performed only by authorized personnel.
Precautions
Observe the country-specific regulations when installing
the device.
The electrical connection of the device is only allowed to
be made with the device isolated.
The wiring of the device must comply with the
instructions in this user information, otherwise there is a
risk that the safety function will be lost.
It is not allowed to open the device, tamper with the
device or bypass the safety devices.
A safe transformer according to IEC 61558-2-6 or a
Electrical
power supply unit with electrical isolation from the
Connection
mains must be connected.
External fusing of the safety contacts must be provided.
A maximum length of the control lines of 1000 meters
with a line cross section of 0.75 mm
exceeded.
The line cross section must not exceed 2.5 mm
If the device does not function after commissioning, it
must be returned to the manufacturer unopened. Ope-
ning the device will void the warranty.
H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Germany
Tel +49 (0)241 9105010 • Fax +49 (0)241 91050138 • info@zander-aachen.de • www.zander-aachen.de
English translation
2 start behavior possible:
- Monitored manual start
- Automatic start
Up to PL e, SILCL 3, category 4
STOP-category: 0
Fig. 1 Block diagramm SR7C
Fig. 2 Installation / removal
All relevant safety regulations and standards are to be
observed.
The overall concept of the control system in which the
device is incorporated must be validated by the user.
Failure to observe the safety regulations can result in
death, serious injury and serious damage.
Note down the version of the product (see label "Ver: x")
and check it prior to every commissioning of a new
device. If the version has changed, the overall concept of
the control system in which the device is incorporated
must be validated again by the user.
2
must not be
2
.
A1:
Power Supply
A2 :
Power Supplay
S11:
DC 24V control voltage
S10:
Control line
S12:
Control line
S13:
Control line
S14:
Control line
S21:
Start, Control line
O1;O2:
Aux transistor outputs
0V:
Reference common O1, O2
81-82:
Auxiliary Contact
91-92:
Auxiliary Contact
101-102: Auxiliary Contact
101-112: Auxiliary Contact
13-14 bis 73-74:
Safety Out1-7
Fig. 3 Connections
H10
Ver. A
E61-141-00
1

Advertisement

loading

Summary of Contents for Zander Aachen SR7C

  • Page 1 Emergency Stop Safety Relay SR7C User Information English translation The SR7C is a universal emergency stop safety switching device Correct Use with seven safe relay outputs that can quickly and safely stop the moving parts of a machine or system in case of danger.
  • Page 2 Emergency Stop Safety Relay SR7C User Information Applications Depending on the application or the result of the risk assessment according to EN ISO 13849-1, the device must be wired as shown in Fig. 1 to Fig. 11. Emergency Stop Fig. 1: Fig.
  • Page 3 Additional data can be requested from the manufacturer for According to applications that deviate from these conditions. EN ISO 13849-1 Safety characteristics according to EN ISO 13849-1 for all variants of SR7C Load (DC-13; 24 V) <= 0,1 A <= 1 A <= 2 A...
  • Page 4 Plug-In Terminals Terminals Dimension Drawing Variants Order No. 472242 SR7C, 24 V AC/DC (50-60 Hz), fixed screw terminals Order No. 472252 SR7C, 24 V AC/DC (50-60 Hz), without plug-in terminals Order No. 474242 SR7C, 24 V AC/DC (50-60 Hz), incl. plug-in screw terminals Order No.