Full Gauge Controls ICEMATIC II Quick Start Manual

Full Gauge Controls ICEMATIC II Quick Start Manual

Cyclic timer

Advertisement

Quick Links

Have this manual in the palm of
your hand by FG Finder application.
WARNING
BEFORE THE INSTALLATION OF THE CONVERTER, WE RECOMMEND READING THE
INSTRUCTION MANUAL IN FULL TO PREVENT POSSIBLE DAMAGE TO THE PRODUCT.
PRODUCT INSTALLATION PRECAUTIONS:
Before performing any procedure on this instrument, disconnect it from the power grid;
Ensure that it has adequate ventilation, avoiding installation on control panels containing devices that
could cause it to operate outside its specified temperature range;
Install the product away from sources that may generate electromagnetic disturbances, such as:
motors, contactors, relays, electrovalves, etc.;
AUTHORIZED SERVICES:
The installation and maintenance of the product must be performed by qualified personnel only;
ACESSORIES:
Use only Full Gauge Controls original accessories.
If you have any queries, please contact our technical support.
THROUGH CONTINUOUS DEVELOPMENT, FULL GAUGE CONTROLS RESERVES THE RIGHT TO
CHANGE THIS MANUAL INFORMATION AT ANY TIME, WITHOUT PRIOR NOTICE.
1. DESCRIPTION
ICEMATIC II is a cyclic timer programmable by setting the output ON and OFF times. It allows an
adjustment of up to 12 hours to keep the control output activated and an adjustment of up to 60 minutes
to keep the control output off.
It is equipped with a controller power up protection, ensuring that the control output (ON) is activated
only after a minimum of two minutes. The green LED will keep flashing during this time, indicating that
the controller is counting time before activating the output.
It also has a dedicated key to reverse the output state manually, always respecting the two-minute time
before activating the control output (ON).
2. APPLICATIONS
- ICEMATIC II can be used as a timer for any type of cyclic event, such as : regulating cooling and
defrost cycles in chambers and chambers and frigorific displays, activating lights, air conditioners,
among others. In the irrigation of plantations, it can control the operation of motor pumps or solenoid
valves for water.
3. TECHNICAL SPECIFICATIONS
Power supply
Accuracy
Output on time
Output off time
Maximum current
Dimensions
*Regarding the accuracy of the controller's internal timing. The accuracy of the configured time also
depends on the adjustment made by the user.
4. OPERATIONS
ICEMATIC II is a cyclic timer that allows the configuration of the time that the respective
output will remain activated by setting the ON time and the OFF time. Upon power up,
ICEMATIC II waits two minutes before activating the ON output. The green LED will keep
flashing
ddd
during this time, indicating that the output will be activated after that time has
elapsed.
4.1 ON time adjustment:
6
8
4
The on T time (ON) can be configured with values between
2
10
00:02 and 12 hours. Whenever the controller is counting the
T (ON) time, the green LED will remain on
0
02
12 hrs
output (NO contact) will remain activated.
T
(ON)
4.2 OFF time adjustment:
30
20
40
The off T time (OFF) can be configured with values between
50
10
2 and 60 minutes. Whenever the controller is counting the T
(OFF) time, the red LED will remain on
output (NO contact) will remain off.
2
60 min
T
(OFF)
ICEMATIC II
CYCLIC TIMER
85~265Vac / 50/60Hz
±3%*
0:02 to 12 hours
From 2 to 60 minutes
16(8) A / 250Vac 1HP
68,5 x 81,0 x 28,0 mm (2,70 x 3,19 x 1,10 in)
ddd
and the main
ddd
and the main
4.3 Output state reversing button:
With one touch (1second) on the key you can manually
switch the output state. If the key is pressed while the
controller is counting the minimum off output time (two
minutes), the green LED will start flashing
that the ON output will be activated after this time has
elapsed.
5. TEST MODE
ICEMATIC II also has a setting that allows changing the output state every two minutes. This
operating mode can be used for functional tests of the equipment on which the controller is
installed. To perform this test, simply set the two time values in the minimum range of the scale,
as shown in the image below:
6
4
2
0
02
T
(ON)
6. SIGNALING
LED STATUS / State
Green / On
Green / Flashing
Red / On
Green - Yellow - Red / Flashing
7. CONNECTION SCHEMATIC
6
4
2
0
02
T
(ON)
L1
L2
85~265Vac / 50/60Hz
ddd
30
20
40
8
10
10
50
12
hrs
2
60
min
T
(OFF)
Occurrence
Counting the configured output ON
time.
Waiting the two minutes of protection
before activating the ON output.
Counting the configured output OFF
time.
Contact Full Gauge Controls.
30
8
20
40
10
10
50
12 hrs
2
60 min
T
(OFF)
CARGA
L1
L2
Power:
Output:
16(8) A / 250Vac 1HP
, indicating
Output
Output
on
Output
off
Output
off
Output
off

Advertisement

loading

Summary of Contents for Full Gauge Controls ICEMATIC II

  • Page 1 It also has a dedicated key to reverse the output state manually, always respecting the two-minute time before activating the control output (ON). 6. SIGNALING 2. APPLICATIONS - ICEMATIC II can be used as a timer for any type of cyclic event, such as : regulating cooling and Output LED STATUS / State Occurrence defrost cycles in chambers and chambers and frigorific displays, activating lights, air conditioners,...
  • Page 2 The packages material are 100% recyclable. Just dispose it through specialized recyclers. Product: The electro components of Full Gauge Controls controllers can be recycled or reused if it is disassembled for specialized companies. Disposal: Do not burn or throw in domestic garbage the controllers which have reached the end-of- life.