5

Operation

5.1

Requirements

In order to connect the device the following conditions apply:
 ibaNet fiber optic (FO) connections and cabling
 In copy mode:
Input: Any iba device with ibaNet FO output
Outputs: Any iba device with ibaNet FO input (some restrictions apply)
 In distribution mode:
Input: iba devices with 32 Mbit/s FO output
Outputs: iba devices with 3.3 Mbit/s FO input
5.2

Application

5.2.1

Copy mode

5.2.1.1
Connecting a measurement device with 2 or more computers
The measured signals from a bus module, e. g. ibaBM-DPM-S, or from an ibaPADU-S
station can be made available to multiple systems by means of ibaBM-DIS-i-8o. The
receiving systems may be:
 ibaPDA, e. g. for process monitoring and troubleshooting
 ibaQDR, e. g. for recording of product and quality data
 ibaLogic, e. g. for process control
Figure 7: Connecting one measurement device (e. g. ibaPADU-8) with 2 or more computers