TROUBLESHOOTING
The face of the Showstopper 3 Accessory Hub has 2 indicator lights on the faceplate and one
indicator light on the red mushroom button to help determine the state of the system. The chart
below should help you diagnose any issues.
Indicator
Ready
Power
Mushroom
When the Green and Amber lights are illuminated, you are ready to Make It Move!
Issue
No indicators illuminated
Red & amber indicators
Amber indicator
All connected Stagehands are not
releasing E-Stop
One of several Stagehands is not
releasing E-Stop
Showstopper Accessories
unresponsive
Refer to the specific device manual for further troubleshooting.
Check
Local
Mains
E-Stop
Power
Engaged
-
-
-
-
Checkpoint
Check mains power
Check E-Stop mushroom switch on the Showstopper E-Stop
Hub
Confirm no remote E-Stop switch is activated
1. Confirm the Base has power
2. Confirm no remote E-Stop switch is activated
1. Confirm Stagehand is connected to Base or E-Stop
2. Replace Showstopper cable between Base or E-Stop
1. Confirm accessory cable is connected
2. Confirm terminations
Remote
E-Stop
Engaged
-
-
Hub with Showstopper cable
Hub and the Stagehand
Showstopper 3 Base Reference Manual
Published 4-14-20
Check
Ready to
Accessory
Make it Move!
connections
and
Terminators
-
-
-
Page 4 of 7