TROUBLESHOOTING 
The face of the Showstopper 3 Accessory Hub has 2 indicator lights on the faceplate and one 
indicator light on the red mushroom button to help determine the state of the system. The chart 
below should help you diagnose any issues. 
Indicator 
Ready 
Power 
Mushroom 
 

When the Green and Amber lights are illuminated, you are ready to Make It Move!

Issue
 
No indicators illuminated 
Red & amber indicators 
Amber indicator 
All connected Stagehands are not 
releasing E-Stop 
One of several Stagehands is not 
releasing E-Stop 
Showstopper Accessories 
unresponsive 

Refer to the specific device manual for further troubleshooting.

Check  
Local  
Mains  
E-Stop 
Power 
Engaged 
 
 
Checkpoint
Check mains power 
Check E-Stop mushroom switch on the Showstopper E-Stop 
Hub 
Confirm no remote E-Stop switch is activated 
1. Confirm the Base has power 
2. Confirm no remote E-Stop switch is activated 
1. Confirm Stagehand is connected to Base or E-Stop 
2. Replace Showstopper cable between Base or E-Stop 
1. Confirm accessory cable is connected 
2. Confirm terminations 
Remote 
E-Stop 
Engaged 
 
 
Hub with Showstopper cable 
Hub and the Stagehand 
 
Showstopper 3 Base Reference Manual 
Published 4-14-20 
Check 
Ready to 
Accessory 
Make it Move! 
connections 
and 
Terminators 
 
 
 
 
 
 