6. troubleshootiNG
fault
Pressure drop in the tank.
Pressure switch valve leaks when
compressor is idle.
Compressor stops and does not restart.
Compressor does not stop at max. pressure.
Compressor noisy with metallic knock.
Weee reGulAtioNs
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
eNviroNmeNt protectioN
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
sealey Group, kempson Way, suffolk business park, bury st edmunds, suffolk. ip32 7Ar
01284 757500
© Jack Sealey limited
cause
Air leaks at connections.
non-return valve seal defective.
motor failure.
Pressure switch fault.
Head gasket or valve fault.
Bearing or piston damage.
01284 703534
sales@sealey.co.uk
Original Language Version
remedy
Run compressor to max. pressure, switch off
unit. Brush soap solution over connections
and look for bubbles. Tighten connections
showing leaks.
If problem persists contact Authorised
Service Agent.
empty the air tank, remove the non-return
valve cap (fig.5.2) and clean, or if necessary,
replace the seal (fig.5.1). Located under
motor cowling.
Contact Authorised Service Agent.
Contact Authorised Service Agent.
Contact Authorised Service Agent.
Contact Authorised Service Agent.