Test Point Diagram - Mitsubishi Electric Mr.Slim PKA Series Service Manual

Wall mounted air conditioners
Hide thumbs Also See for Mr.Slim PKA Series:
Table of Contents

Advertisement

9-7. TEST POINT DIAGRAM

Indoor controller board
CN2L
Connector
(LOSSNAY)
LED1: Power
supply (I.B)
CN105
IT Terminal
CN4F
Float switch (FS)
(option)
CN41
Connector
(HA terminal-A)
SWE
Emergency
operation connector
CN51
Centrally control
CN32
Remote switch
LED3: Transmission
(Indoor/Outdoor)
SW1
Model selection
SW2
Capacity setting
Jumper wire J41,J42
Pair No. setting for
wireless remote controller
OCH758
CNP Drain pump output
1–3: 13 VDC
(option)
LED2: Power
CNV
supply (Wired
Vane motor
remote controller)
(MV1, MV2)
12 VDC pulse outlet
CN20
Room temp.
thermistor (TH1)
27
CNMF
Connect to the
fan motor (MF)
1–3 : 310–340 VDC
4–3 : 15 V DC
5–3 : 0–6.5 VDC
6–3 : 0 or 15 VDC
CN01
Connect to the
Terminal block (TB4)
1–3 : 220–240 V AC
FUSE
(3.15 A 250 V)
CN3C
Transmission
(Indoor/outdoor)
(0–28 VDC)
CN44
Pipe temperature
thermistor
1–2 : Liquid (TH2)
3–4 : Condenser/
Evaporator(TH5)
CN90
Connect to the remote
operation adapter
CN22
Connect to the terminal
block (TB5) (Remote
controller connecting
wire) (option)
CNRU
Connect to SWITCH BOARD
(S.B), LED BOARD (L.B) and
PCB for WIRELESS REMOTE
CONTROLLER (option)