Advertisement

AIR CONSUMPTION/BPM
*Estimated values 400–500 psi (27,6-34,5 bar)
100 psi / 6,9 bar (scfm / L/s)
100 psi (bpm)
150 psi / 10,3 bar (scfm / L/s)
150 psi (bpm)
200 psi / 13,8 bar (scfm / L/s)
200 psi (bpm)
250 psi / 17,2 bar (scfm / L/s)
250 psi (bpm)
300 psi / 20,7 bar (scfm / L/s)
300 psi (bpm)
350 psi / 24,1 bar (scfm / L/s)
350 psi (bpm)
400 psi / 27,6 bar (scfm /
L/s)*
400 psi (bpm)
435 psi / 30 bar (scfm /
L/s)*
435 psi (bpm)*
450 psi / 31 bar (scfm /
L/s)*
450 psi (bpm)*
500 psi / 34,5 bar (scfm /
L/s)*
500 psi (bpm)*
QLX 35
Imperial
Metric Imperial
142
67
111
1289
219
103
229
1509
288
136
331
1699
348
164
441
1858
400
189
555
1987
444
210
675
2087
645
275
781
2293
847
340
859
2500
893
1063
QLX 40
Metric
52
1107
108
1252
156
1419
208
1591
262
1759
319
1872
369
2053
406
2163
421
2211
474
2368
23