9. TECHNICAL DATA

9.1 Hob dimensions
Width
Depth
9.2 Other technical data
TOTAL POW‐
ER:
Electric supply:
Appliance cate‐
gory:
Gas connec‐
tion:
Appliance
class:
9.3 Gas burners for LPG G30/G31 30/30 mbar
BURNER
Multi Crown
Semi-rapid
Auxiliary
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
Multi Crown
Semi-rapid
Auxiliary
10. ENVIRONMENTAL CONCERNS
Recycle materials with the symbol
Put the packaging in relevant containers
to recycle it. Help protect the
environment and human health by
recycling waste of electrical and
G30/G31 (3B/P) 30/30
Gas original:
mbar
Gas replace‐
G20 (2H) 20 mbar
ment:
220-240 V ~ 50-60 Hz
II2H3B/P
R 1/2"
3
NORMAL
MINIMUM
POWER kW
POWER kW
3,4
1,8
1,9
0,75
1,0
0,47
NORMAL POWER
kW
3,5
1,9
1,0
.
890 mm
510 mm
INJECTOR
MARK
095
71
50
MINIMUM POWER
kW
1,75
0,7
0,38
electronic appliances. Do not dispose of
appliances marked with the symbol
with the household waste. Return the
product to your local recycling facility or
contact your municipal office.
*
ENGLISH
734 g/h
10,2 kW
NOMINAL GAS
FLOW g/h
247
138
73
INJECTOR MARK
146
96x
76X
25