The information in this document is subject to change without notice and is provided as available at the time of printing. Beijer Electronics AB, including all its group companies, reserves the right to change any information without updating this publication. Beijer Electronics AB, including all its group companies, assumes no responsibility for any errors that may appear in this document.
After cleaning the agent should be removed. Ammonia based glass cleaners (typically 5-10% ammonia) or 75% alcohol can be used to clean the surface of PCAP and resistive touch panels. When you clean the surface of your touch panel, please follow these steps: Beijer Electronics, MAEN329...
The layer structure of the touch screen contains air. In rare cases, the appearance of bubbles can arise. This is purely cosmetic and does not affect the functionality of the operator panel. The appearance can occur under certain environmental conditions such as temperature, humidity, and atmospheric pressure. Beijer Electronics, MAEN329...
2. To cut a correct opening for the operator panel, use the cut out dimensions in the outline drawing. A separate cut out drawing is available for download from the Beijer Electronics web site. For more information, see sections Operator Panel Drawings Technical Data.
3.2.1 Connections to the Controller For information about the cables to be used when connecting the operator panel to the controller, please refer to the help file for the driver in question. Beijer Electronics, MAEN329...
In the firmware there are some ports that are open by default due to the operating system or that the internal application requires it. Type Description Open by default Project transfer (9999) Netbios (137) Netbios (138) Filtered. Beijer Electronics, MAEN329...
Technical Data Technical Data Parameter X2 base 7 v2 Front panel, W × H × D 202x152x37 mm Cut out dimensions, 186x136 (+/-1) mm W × H Mounting depth 32 mm (132 mm including clearance) Mounting Switchboard installation Front panel seal...
Page 12
Technical Data Parameter X2 base 7 v2 Power supply +24 VDC (18-32 V DC) CE: The power supply must conform with the requirements according to EN/IEC 60950 and EN/IEC 61558-2-4. UL and cUL: The power supply must conform with the requirements for class 2 power supplies.
The Autoflex protective film is not resistant to high pressure steam at over 100 °C or the following chemicals: Concentrated mineral acids Benzyl alcohol Concentrated caustic solution Methylene chloride Beijer Electronics, MAEN329...
5.1.3 Touch Screen Protector For harsh environments and exposure to outdoor conditions, it is recommended to use a protective film to guard the touch screen from damage. This optional part can be ordered from Beijer Electronics. Beijer Electronics, MAEN329...
Power Ground Frame Ground (b) COM-A port connector DSUB Short Name COM-A scrip- tion DSUB-9, female, right-angle Refer- ence Kycon K202XHT series CLASS C Comment Signal Alternate Signal RS422_TX+ RS485-1_+ RS232_RxD RS232_TxD RS422_RX+ RS485-2_+ RS422-TX- RS485-1_- RS232_RTS Beijer Electronics, MAEN329...
Page 16
Cvilux CU01SAH1S00 CLASS C Signal Comment 5.0V from dedicated USB power switch Output VBUS (5V) Current: 0.5A (continuous) USB- USB 2.0 Negative USB+ USB 2.0 Positive Connector Shell (housing) is connected according to chapter 4.5.1 and 4.5.2 Beijer Electronics, MAEN329...
Page 17
RS485 should use 5V signaling level on the bus side.A Common mode filter is recommended for RS485 differential pairs.All signals should have ESD protection. (i) Grounding Short Name Grounding scrip- tion Shield connector for COM-C Screw M3x10 Phillips Beijer Electronics, MAEN329...
Operator Panel Drawings X2 base 7 v2 Outline Note: A Step CAD file is available on the web site www.beijerelectronics.com v2 HP X2 base 7 v2 X2 base 7 v2 HP Beijer Electronics, MAEN329...
Page 19
Operator Panel Drawings Note: Minimum thickness for the front plate is 2.0 mm. Beijer Electronics, MAEN329...
3 turns around the ferrite core provide 9 times the suppression of 1 turn. Connect a wire or grounding braid, that is sized correctly according to local electrical codes, between the chassis of the operator panel and the closest grounding point. Beijer Electronics, MAEN329...
1. Check whether the other Ethernet unit has its shield directly grounded or grounded via a capacitor. Note: In many cases, connecting the shielded Ethernet cabling to the chassis at both ends is inappropriate. Hum or grounding loops can occur. Unshielded cabling may even result in fewer communication errors. Beijer Electronics, MAEN329...
This connects the HF transients to ground. To Achieve Better EMC Protection • Initially, use the original cabling from Beijer Electronics primarily. • Place the 24 V DC and communications cabling in one cable trunk/cable duct and 230/380 V AC in another. If the cables need to be crossed, cross them at 90°...
In most cases, the ambient temperature for the operator panel is significantly higher than the device cabinet’s ambient temperature. If the cabinet is tall and there are a number of heat-generating devices, the temperature at the top of the cabinet is considerably higher than the temperature Beijer Electronics, MAEN329...
Page 24
An approximate value of the net power consumption for the operator panel can be calculated by multiplying the supply voltage with the current drawn by the operator panel. This is assuming that all supplied power is transformed to heat. Beijer Electronics, MAEN329...
Transients on the 24 V feed are connected to the ground. • No risk that the 24 V feed is at a high level in relationship to the ground. This is not unusual since there is high static electricity. Beijer Electronics, MAEN329...
RS-422/RS-485 and USB. Only the Ethernet connection has galvanic isolation. The operator panel has galvanic isolation against the 24 V DC power supply but no galvanic isolation between the communication ports for RS-232, RS-422/RS-485 and USB. Only the Ethernet- and RS-485 connection have galvanic isolation. Beijer Electronics, MAEN329...
Page 27
24 V feed, disturbances and grounding currents from the 0 V on the 24 V side disrupt the communication. Using this type of unit solves one problem but creates a larger problem! A substandard installation may work now, but problems may arise when other devices are connected. Beijer Electronics, MAEN329...
Depending on the recipients’ design, the bus wires may be on the same level or require pull-up or pull-down to ensure that no faulty signals are detected when the bus is in resting mode (all transmitters are disconnected). Beijer Electronics, MAEN329...
Page 29