TURBOJET MAX & MAX II TurboJet TurboJet Max II Division of D.P.L. Enterprises Inc. 3868 East Post Road, Las Vegas, Nevada 89120, (702) 454-5515, FAX (702) 454-5225 Website: www.air-care.com; E-mail: Info@Air-Care.com...
TurboJet Max & Max II TABLE OF CONTENTS CHAPTER PAGE Unpacking Instructions Safety Precautions Handle Installation Set-Up and Testing Duct Cleaning Procedures Troubleshooting Guide Maintenance Parts and Accessories Optional Parts and Accessories Specifications Glossary & Acronyms Limited Warranty Page 3...
Check that all parts are present (See Page 10) TurboJet Max Main Assembly, with Wheels, Motor and Blower. Release the 4 side latches and lift the front of the upper section so it hinges up to check for filters. The HEPA filter will remain in the bottom section, the First Stage, 2”...
TurboJet Max & Max II HANDLE INSTALLATION Handle is bubble wrapped and packed near the bottom, front of TurboJet. It must be installed with the 4 bolts provided and your ½” socket wrench or nut driver. Page 5...
TurboJet Max & Max II SET-UP AND TESTING Air-Care TurboJet Negative air machines are designed to “Pull” loose debris out of the air system to which they are connected and filter out harmful debris such as pollen, dust, mold spores and other debris with its 3 stage HEPA filter system.
Page 7
TurboJet Max & Max II DUCT CLEANING PROCEDURES (CONTINUED) duct is very effective. Gravity will help “pull” dust and debris into the Turbojet. In some cases, it may be best to attach the TurboJet to each Supply or return duct and insert the agitation device into that same duct opening to disturb debris as far up stream and down stream as possible.
Page 8
TurboJet Max & Max II DUCT CLEANING PROCEDURES (CONTINUED) 8. The TurboJet Max 2 can be 9. After all ducts are cleaned, 7. Then turn on the start switch set to “High” speed. the ducts can be fogged with an...
TurboJet Max & Max II TROUBLESHOOTING GUIDE Symptom Check Corrective Action Check connections to motor and control panel. Test motor and replace if bad. Check for manual reset button on Motor does not start motor. when power switch is “Power” light on? turned on.
Page 10
TurboJet Max & Max II TROUBLESHOOTING GUIDE (CONTINUED) Inverter Troubleshooting Guide DIAGNOSTIC LEDS The drive contains two diagnostic LEDs to display the drive’s operational status. See page 12, for the location of the PWR and “ST” LEDs. Power On (PWR) - The “PWR” LED will illuminate green when the AC line is applied to the drive Status LED (ST) - The “ST”...
2. When necessary, wash the 2nd stage filters with a garden hose and nozzle at full force. First rinse in the opposite direction of the airflow, then rinse both sides. Occasionally, a degreaser such as Air-Care Zap electrostatic filter cleaner may be required to restore this filter to its’ peak performance.
Page 12
2. When necessary, wash the 2nd stage filters with a garden hose and nozzle at full force. First rinse in the opposite direction of the airflow, then rinse both sides. Occasionally, a degreaser such as Air-Care Zap electrostatic filter cleaner may be required to restore this filter to its’ peak performance. Let the filter air dry before reinstalling into the unit.
COMPLETE ASSEMLY (Two Speed) CE2015 Owners Manual For TuboJet Max and Max II MM0193 TurboJet Max Main Assembly, with Wheels, Motor and Blower in tact Call First stage, 18” x 24” x 2” Disposable Pleated Filter F1686 Second stage, 19” x 25” x 1” 82% Electrostatic Air Filter F1826 Third stage, 18”...
Page 14
Sidewinder Hose Assembly CE1542A HEPA Back Pack Vacuum 120 Volt (for 220 V Call) CE2297C Panel with all Components for Single Speed TurboJet Max CE4211A Panel with all parts for Two Speed TurboJet Max-2 CE4210 Not Shown Motor, 230 Volt, 3 Phase (For Max 2 ONLY)
Page 15
TurboJet Max & Max II PARTS AND ACCESSORIES (CONTINUED) Power Receptacle 120 Volts AC 13 Amps (220V Model: 6.5 Amps) Serial Made in USA by Air-Care Division of DPL Enterprises, Inc., Circuit Breaker Las Vegas, NV HIGH 120 Volts AC Low = 13 Amps, Hight = 18 Amps (220V Model: Low = 6.5 Amps, High = 9 Amps)
SPECIFICATIONS Specification Description Size 19.5” W x 29” D x 55 ½” H Weight 125 lbs. Power required 120 V, 60 Hz, 13 to 17 amps. Power Cord 25’ Extension Cord Filtration 4 stages when Pellon pre-filter used Pre-Filter Pellon Moisture Barrier 1st Stage 18”...
TurboJet Max & Max II GLOSSARY & ACRONYMS 1. ACGIH — American Conference of Government Industrial Hygienists 2. ASHRAE — American Society of Heating, Refrigerating, and Air Conditioning Engineers 3. Air Handler/ AHU — The Furnace or air conditioner that heats, cools and moves the air.
Page 19
TurboJet Max & Max II GLOSSARY & ACRONYMS (CONTINUED) 25. MSDS — Material Safety Data Sheet 26. Make-up Air — Fresh “outside” air that is brought into a Commercial building. 27. NADCA — National Air Duct Cleaners Association 28. NAFA — National Air Filter Association 29.