• After the installation work, confi rm that refrigerant gas does
not leak. If refrigerant gas leaks into the room and fl ows near
a fi re source, such as a cooking range, noxious gas may be
generated.
• When the air conditioner has been installed or relocated,
follow the instructions in the Installation Manual and purge
the air completely so that no gases other than the refrigerant
will be mixed in the refrigerating cycle. Failure to purge the air
completely may cause the air conditioner to malfunction.
• Nitrogen gas must be used for the airtight test.
• The charge hose must be connected tightly and in a proper
manner.
Electrical wiring
• Only a qualifi ed installer (*1) or qualifi ed service person (*1) is
allowed to carry out the electrical work of the air conditioner.
Under no circumstances must this work be done by an
unqualifi ed individual since failure to carry out the work properly
may result in electric shocks and/or electrical leaks.
• To connect the electrical wires, repair the electrical parts or
undertake other electrical jobs, wear gloves to provide protection
for electricians, insulating shoes and clothing to provide
protection from electric shocks. Failure to wear this protective
gear may result in electric shocks.
• Use wiring that meets the specifi cations in the Installation
Manual and the stipulations in the local regulations and laws.
Use of wiring which does not meet the specifi cations may give
rise to electric shocks, electrical leakage, smoking and/or a fi re.
• Connect earth wire. (Grounding work) Incomplete earthing
causes an electric shock.
• Do not connect earth wires to gas pipes, water pipes, and
lightning conductor or telephone earth wires.
• After completing the repair or relocation work, check that the
earth wires are connected properly.
9-EN
– 5 –
• Install a circuit breaker that meets the specifi cations in the
installation manual and the stipulations in the local regulations
and laws.
• Install the circuit breaker where it can be easily accessed by the
agent.
• When installing the circuit breaker outdoors, install one which is
designed to be used outdoors.
• Under no circumstances, the power supply wire or the indoor
and outdoor connecting wire must be connected in the middle
(Connection using a solderless terminal etc.).
Connection trouble in the places where the wire is connected in
the middle may give rise to smoking and/or a fi re.
• Electrical wiring work shall be conducted according to law and
regulation in the community and installation manual.Failure to do
so may result in electrocution or short circuit.
Test run
• Before operating the air conditioner after having completed the
work, check that the electrical control box cover of the indoor
unit and service panel of the outdoor unit are closed, and set the
circuit breaker to the ON position. You may receive an electric
shock if the power is turned on without fi rst conducting these
checks.
• If there is any kind of trouble (such as check code display has
appeared, smell of burning, abnormal sounds, the air conditioner
fails to cool or heat or water is leaking) has occurred in the air
conditioner, do not touch the air conditioner yourself but set
the circuit breaker to the OFF position, and contact a qualifi ed
service person. Take steps to ensure that the power will not be
turned on (by marking "out of service" near the circuit breaker, for
instance) until qualifi ed service person arrives. Continuing to use
the air conditioner in the trouble status may cause mechanical
problems to escalate or result in electric shocks or other trouble.