Download Print this page

gefran SBI-DCP-33 Instruction Manual page 13

Dcp interface card for avyl drive

Advertisement

Available languages

Available languages

6 - Encoder phasing
6059
Cmp 2 function
4068
DO 3 src
9076
Fault reset src
4200
CCF restart On
4201
CCF restart time
After importing the recipe, send the SAVE CONFIG command from
the STARTUP menu.
Switch the drive off and then back on again to establish the communi-
cation with the DCP card.
When using drives connected to synchronous motors and if encoder
phasing is required, phasing can be performed automatically using
the DCP master controller keypad:
- from REGULATION PARM \ Flux config \ Magnetiz config
-
select Auto phase rot or Auto phase still
- wait until the "Wait ..." message is displayed
-
set the master controller to "Inspection mode"
- send the Start command (this must be sent within 10 seconds,
otherwise the procedure is cancelled).
I0 OR I1 OR I2
B0 W1 decomp
B0 W1 decomp
5000.000000
ENGLISH - 13

Advertisement

loading