Miller ProHeat Rolling Inductor Faq
Hide thumbs Also See for ProHeat Rolling Inductor:

Advertisement

Quick Links

Q: How do I access the program setup screen for the Rolling Inductor?
A: To view the system setup screen for the Rolling Inductor, simultaneously press the
Parameters and Program buttons. The following settings are available:
 Deg Units Displayed (°F or °C)
 Tolerance (±5 to 99)
 Travel Detect (On or Off)
 Control Mode (Manual, Temp, Time or Remote)
 Max Output (1 Kw to 35 Kw)
 System Lock (Yes or No)
(For more information on the setup screen, please consult the Rolling Inductor Owner's
Manual)
Q: Can I get a full 35 kW of output power with the Rolling Inductor?
A: No, the Rolling Inductor is limited to 300 amps which results in about 20 kW of output
power. If 35 kW at 100% duty cycle is desired, a two rolling inductor arrangement is
required. The external cooler heat exchanger (300993) is recommended for two Rolling
Inductor arrangements. (See owner's manual for additional information on this topic)
Q: If I already own a ProHeat 35, will the Rolling Inductor work with my system?
A: Yes, all ProHeat 35 systems are capable of running the Rolling Inductor, but if the system was
purchased before August 2014 (serial number prior to ME320092G) a software update is
required to run the Rolling Inductor and a hardware update is required to run the Travel
Detect System (301183). If an update is needed, call Miller's service department at 920-735-
4001 for more information on how to update your systems software.
Q: Will the Rolling Inductor work with the Intellifire 250 or other induction power sources?
A: No. The ProHeat 35 is the only power source that works with the Rolling Inductor.

ProHeat Rolling Inductor FAQ

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ProHeat Rolling Inductor and is the answer not in the manual?

Questions and answers

Summary of Contents for Miller ProHeat Rolling Inductor

  • Page 1 Rolling Inductor and a hardware update is required to run the Travel Detect System (301183). If an update is needed, call Miller’s service department at 920-735- 4001 for more information on how to update your systems software.
  • Page 2 Q: What’s the difference between the mounting arm and mounting stand that Miller offers? A: The mounting arm (301119) allows heating from the top side of the pipe and will provide the most amount of flexibility and configurability.
  • Page 3 Q: Who can I contact for additional support or information about the Rolling Inductor? A: For more information regarding setup, troubleshooting, or operation of the Rolling Inductor contact Miller’s service department at 920-735-4001...

This manual is also suitable for:

301263301117

Table of Contents