  • Page 2 A OXYMETER PROBE 1- PRESENTATION The Oxymeter is a luminescence technology-based tool that measures oxygen and that can be operated with a smartphone or a tablet. The Oxymeter is used to measure dissolved Oxygen in liquid. The Oxymeter has a dipping probe and a power and communication box (not submersible) 2- MEASUREMENT IN A TANK The Oxymeter can be used for dissolved Oxygen...
  • Page 3 B- PERFORM AND MANAGE MEASUREMENTS 1- INSTALL THE MOBILE APP Accept Privacy Policy of PreSens Wireless Studio a. Prerequisites The App Presens Wireless Studio (PWS) is is compatible with all smartphones with at least Android 6.0 or iOS 9.0 that support Bluetooth Low Energy. b.
  • Page 4 Press SCAN and allows PWS to access location All nearby compatible devices should appear on the screen. If no device appears, please check : - Bluetooth is activated on your smartphone - A compatible device is nearby (10m) - the device to connect still has battery power. - the device to connect is not connected to another smartphone (in this case the device is no longer visible for others smartphone)
  • Page 5 2- USE OF OXYMETER a. Modify the calibration This step, must be done only in the event of replacement of the CAP. From the PARAMETERS menu, select Manual Calibration, entering the calibration’s parameters shown on the Final Inspection Protocol which comes with the replacement CAP.
  • Page 6 b. Settings Change O unit Androïd c. Start a measurement Measurement - Parameters can be modified by pressing the value (exple Humid) - Only the parameter Unit and sometimes Temperature measurement must be modified. - The change must be validated “save” or canceled “cancel”...
  • Page 7 From Live View menu, there are two ways to launch a d. Export data measurement From MEASUREMENTS menu, you can access all the data recorded by the Oxymeter. The data are sorted by - Press START : a continuous measurement is launched , timestamp.
  • Page 8: Calibration Check

    When the battery level indicator shows a low level, it is necessary to change all the batteries. In the case of batteries replacement, perform a single measurement SINGLE to refresh the battery indicator level. In case of deep discharge of the batteries: the charger may display NULL.
  • Page 9 CONTACT winequalitysolutions@vinventions.com Mobile: +33 6 84 42 71 88 Office: +33 9 77 48 06 81 Address 7 Avenue Yves Cazeaux 30230 Rodilhan France WWW.WINEQUALITYSOLUTIONS.COM W W W.V I N V E N T I O N S . CO M...