Page 1
ICS™ Stand II User Manual ORTEC® Part No. 1108265 Manual Revision B, ORT-X4548...
Page 3
NOTICE OF PROPRIETARY PROPERTY — This document and the information contained in it are the proprietary property of AMETEK Inc., ORTEC Business Unit. It may not be copied or used in any manner nor may any of the information in or upon it be...
Page 4
1108265B ICS Stand 2 SAFETY INSTRUCTIONS AND SYMBOLS This manual contains up to three levels of safety instructions that must be observed in order to avoid personal injury and/or damage to equipment or other property. These are: DANGER Indicates a hazard that could result in death or serious bodily harm if the safety instruction is not observed.
If, during unpacking, you find concealed damage, notify the carrier and file a claim. Be sure to save all packing materials, waybills, and other such documentation to establish claims. Contact our Global Service Center or your ORTEC representative for further instructions. All system components and specifications subject to change without notice.
ICS Stand 2 1108265B ICS STAND OVERVIEW 1.3. CONTENTS OF THE SHIPPING CARTON When you receive the ICS Stand, its shipping carton will contain the following components: ● The ICS Stand main assembly. ● User manual and documentation package. ● Pneumatic air pump (for units shipped after November 2015) 1.4.
1108265B ICS Stand 2 1.5. THE ICS STAND Figure 1 illustrates the main features of the ICS Stand (shown without the ICS and detector).
Page 9
ICS Stand 2 1108265B Plug support plate Mount panel Air piston Schrader air valve Directional selection lever Adjustable feet (4) Figure 1. ICS Stand 2 fully compressed.
1108265B ICS Stand 2 ICS INSTALLATION ONTO THE ICS STAND Tools required: • One hex wrench (included) • One pneumatic air pump with a Schrader valve, such as a bicycle pump (included) 2.1. THE ICS AND ICS STAND ASSEMBLY 1) Remove the plug support plate by lifting the plate off the main bracket (no tools necessary). 2) Connect the air pump to the Schrader valve.
Page 11
ICS Stand 2 1108265B 3) Flip the directional valve to the up position. 4) Use the air pump to raise the platform about 6 inches (150 mm).
Page 12
1108265B ICS Stand 2 5) Place ICS on the platform. (ICS-P4 shown)
Page 13
ICS Stand 2 1108265B 6) If a secondary plug is used in the shield installation, re-install the plug support plate. No tools are necessary. The plate slides into position. Installation of the plate is meant to be snug. If a secondary plug is not used, it is not necessary to reinstall the plug plate.
1108265B ICS Stand 2 INSTALLATION UNDER A TYPICAL 4” TOP LOADING LEAD SHIELD 3.1. Preparing the lead shield 1) The installation is for a typical top loading, 4” lead shield. 2) Remove any shield plugs that may be installed so that there is a clear opening in the bottom of the shield large enough to easily accommodate the size of the detector capsule and endcap.
Page 15
ICS Stand 2 1108265B 2) Continue to adjust the position of the ICS Stand to align the detector capsule with the center of the access hole in the shield bottom. 3) Once centered, attach the pneumatic air pump, move the directional selection lever on the front of ...
Page 16
1108265B ICS Stand 2 4) Continue to raise the ICS detector until the proper position is reached. Disconnect the pneumatic air pump and move the directional selection lever to the LOCK ( – ) position. CAUTION: The shield should not electrically contact the cryostat. Plastic sheeting or tape may be used to insulate.
ICS Stand 2 1108265B 3.3. Positioning the ICS and ICS Stand with Inadequate Shield Clearance CAUTION: This procedure requires careful handling and alignment to prevent possible damage to the detector. It is recommended to keep the protective cover on the endcap when installing. Additionally, this installation is NOT recommended for a single person, and multiple individuals should be present to assist.
Page 18
1108265B ICS Stand 2 5) If necessary, adjust the position of the ICS Stand to align the detector capsule with the center of the access hole in the shield bottom. 6) Once centered, attach the pneumatic air pump, move the directional selection lever on the front of ...
Page 19
ICS Stand 2 1108265B 7) Continue to raise the ICS detector until the proper position is reached. Disconnect the pneumatic air pump and move the directional selection lever to the LOCK ( – ) position. CAUTION: The shield should not electrically contact the cryostat. Plastic sheeting or tape may be used to insulate.
ICS Stand 2 LOCKING THE ICS STAND 2 IN POSITION. This is done after the ICS is installed on the stand and the ICS Stand II is in its desired location in the shield. Using the hex wrench provided, torque the lock nut to a maximum of 130 in-...