Download Print this page
Zander Aachen SR3D User Information

Zander Aachen SR3D User Information

Safety emergency stop relay

Advertisement

Quick Links

Safety Emergency Stop Relay SR3D
User Information
SR3D is an all-purpose emergency stop device which ensures the
Correct Use
quick and safe deactivation of the moving parts of a machine in
case of danger.
Applications for the SR3D include single or dual-channel emer-
gency stop circuits and guard monitoring on machines and
plants.
The SR3D is specially designed and certified for the use in
furnaces and ancillary equipment in continuously mode accord-
ing to EN 50156-1 and EN 746-2 and the use on ships, cetified
by Germanischer Llloyd.
3 safety contacts
1 auxiliary contact
Connection of:
- Emergency stop buttons
- Safety switches
- Non-contact safety switches
- OSSD-Outputs
Control: single or dual channel
Feedback loop for external contactors or extension
modules
Redundancy and cyclical monitoring
Diversified forcibly guided output relays
LED indicator for status channel 1 and 2
Function
The emergency stop safety switching device SR3D is
designed for safe isolation of safety circuits according to
EN 60204-1 and can be used up to safety category 4, PL e
according to EN ISO 13849-1.
The internal logical system closes the safety contacts
when the start button is pressed.
If the safety switch is opened, the positively driven safety
contacts are opened and safely switch the machine off. It
is ensured that a single fault does not lead to a loss of the
safety function and that every fault is detected by cyclical
self-monitoring no later than when the system is switched
off and switched on again.
Installation
As per EN 60204-1, the device is intended for installation
in control cabinets with a minimum degree of protection of
IP54. It is mounted on a 35 mm DIN rail according to
DIN EN 60715 TH35.
For the AC 115V/230V type, keep a minimum space of
10mm between the devices.
Safety
Installation and commissioning of the device must be
Precautions
performed only by authorized personnel.
Observe the country-specific regulations when installing
the device.
The electrical connection of the device is only allowed to
be made with the device isolated.
The wiring of the device must comply with the instruc-
tions in this user information, otherwise there is a risk
that the safety function will be lost.
It is not allowed to open the device, tamper with the
device or bypass the safety devices.
Electrical
Consider the information in the section "Techn. data"
Connection
When the 24 V version is used, a safety transformer
according to EN 61558-2-6 or a power supply unit with
electrical isolation from the mains must be connected
External fusing of the safety contacts must be provided.
If the device does not function after commissioning, it
must be returned to the manufacturer unopened. Ope-
ning the device will void the warranty
Increasing service life if driving inductive loads by using
appropriate protective circuitry (e.g. freewheeling diode)
H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Germany
Tel +49 (0)241 9105010 • Fax +49 (0)241 91050138 • info@zander-aachen.de • www.zander-aachen.de
Errors and technical changes reserved
Germanischer Lloyd
Zertifikat TAE00003JF
2 start performances:
- monitored manual start
- automatic start
Short-circuit monitoring and earth fault monitoring
Up to PL e, SILCL 3, category 4
Fig. 1 Block diagram SR3D
Fig. 2 Mounting / Demounting
All relevant safety regulations and standards are to be
observed.
The overall concept of the control system in which the
device is incorporated must be validated by the user.
Failure to observe the safety regulations can result in
death, serious injury and serious damage.
Note down the version of the product (see label "Ver.")
and check it prior to every commissioning of a new de-
vice. If the version has changed, the overall concept of
the control system in which the device is incorporated
must be validated again by the user.
A1:
A2 :
S11:
S10:
S21:
S13:
S14:
S12:
13-14:
Ver. B
23-24:
Pwr: AC/DC 24V
33-34:
41-42:
Note:
Fig. 3 shows the AC/DC 24 V variant.
Fig. 3 Terminals
English translation
Power supply
Power supply
DC 24 V control voltage
Control line
Start control line
Control line
Control line
Control line
Safety contact 1
Safety contact 2
Safety contact 3
Auxiliary contact
M03
Ver. B
E61-139-00
1

Advertisement

loading

Summary of Contents for Zander Aachen SR3D

  • Page 1 The SR3D is specially designed and certified for the use in furnaces and ancillary equipment in continuously mode accord- ing to EN 50156-1 and EN 746-2 and the use on ships, cetified by Germanischer Llloyd.
  • Page 2 • It must be ensured that any switch-on pulses (light test) sent by the signal generator do not lead to a short activation of the safety relay and should therefore basically be deactivated • For applications according to Fig. 7 and Fig. 8 make sure that the ground potential of the signal generator and the SR3D is the same Start Behavior Fig.
  • Page 3: Check And Maintenance

    DIN rail according to EN 60715 TH35 *) If several SR3D-24V are mounted closely together the maximum cumulative current is 9A at an ambient temperature of 20°C or 3 A at 30 °C or 1 A at 40 °C. If the current exceeds these limits, keep a minimum space of 5 mm between the devices.
  • Page 4 Using the SR3D, a safety emergency stop relay according significant consquences. It is therefore recommended to stock a second unit to avoid long downtimes in such a case.
  • Page 5 Safety Emergency Stop Relay SR3D English translation User Information Errors and technical changes reserved Safety Safety characteristics according to EN ISO 13849-1 Charcteristics Load - AC-15 / DC-13 ≤ 1 A / ≤ 1 A ≤ 2A / ≤ 2A ≤...

This manual is also suitable for:

472270472271472272474270474271474272 ... Show all