DRAINING FLUID
• Remove the Inlet Adapter from the Inlet/Spout at the top of the Evacuator by pushing in firmly
and turning 15° Clockwise to unlock the latch.
• Grasp Knob and pull out to remove.
• Contents can splash into eyes. Be sure to follow all precautions listed
on fluid containers before using.
• Wear ANSI Z87.1 approved eye protection while using extractor.
• Wear appropriate chemical resistant gloves while handling fluids.
Used automotive fluids are hazardous materials and should be disposed of
in compliance with local regulations.
• Before proceeding to empty the Fluid
Canister, note the "Fluid Drain Limited
Line" molded into both sides of the Fluid
Canister (FIG 7). Allowing the fluid level
in the Canister to go above this line while
tilting the Canister to empty its contents
may allow fluid to escape through the
built-in Safety Valve.
• Tilt Evacuator Canister to allow accumu-
lated fluid to pour out of Spout.
To avoid leakage from the built-in Safety Valve when draining fluid, DO NOT
allow fluid level in the Canister to exceed the "Fluid Drain Limited Line".

MAINTENANCE

• DO NOT allow fluid to remain in Evacuator Canister.
• DO NOT use Evacuator Canister as a fluid storage vessel.
• Remove Nylon Tube or Silicone Hose when done, allow to drain fully then clean out by flushing
with a suitable solvent.
• If a clog in a Nylon Tube should occur, use the Tube Clog Clearing Wire by inserting into the end
of the tube and pushing until the material causing the clog is discharged.
To order parts and supplies: 800.343.9353 >> eastwood.com
EXPOSURE TO AUTOMOTIVE FLUIDS CAN BE A HEALTH HAZARD!
FIG. 7