Advertisement

User
Manual
PROBLEM?
We can solve 99% of
issues in a quick call
0800 195 0088 or email
info@alcosense.com
WARNING: AlcoSense is a sensitive measurement device. Performing a breath
test less than 10 minutes after drinking risks blowing high levels of alcohol
directly from your mouth into the system which could permanently damage
the sensor and cause the system to read inaccurately. Blood alcohol levels
can continue to rise for up to 90 minutes after drinking, as a result we only
recommend using the Breathalyser after this time (and ideally the morning
after) to ensure your reading will not increase after you test yourself. Do not
blow directly into the blow hole without a blow tube – this can damage the
sensor and significantly reduce the lifetime of your unit.
1
Support: UK 0800 1950088 / IRL 1800 719310 Mon to Fri 0900–1730 info@alcosense.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lite 2 and is the answer not in the manual?

Questions and answers

Summary of Contents for AlcoSense Lite 2

  • Page 1 Do not blow directly into the blow hole without a blow tube – this can damage the sensor and significantly reduce the lifetime of your unit. Support: UK 0800 1950088 / IRL 1800 719310 Mon to Fri 0900–1730 info@alcosense.co.uk...
  • Page 2 Please be aware of the drink drive limit in your jurisdiction. AlcoSense Lite 2 User Manual Version 1.2 Support: UK 0800 1950088 / IRL 1800 719310 Mon to Fri 0900–1730 info@alcosense.co.uk...
  • Page 3: Table Of Contents

    Install the batteries and clean the sensor Set the Drink Drive Alert Level Understanding the Symbols on Screen How to Perform a Breath Test Understanding the Results Maintaining your AlcoSense Breathalyser Recalibration Technical Support Troubleshooting Technical specifications Legal & Warranty...
  • Page 4: How Breathalysers Work

    This is the reason why we do not recommend using the breathalyser just after finishing drinking because there are too many factors that can influence the reading. The ideal time is the morning after. Support: UK 0800 1950088 / IRL 1800 719310 Mon to Fri 0900–1730 info@alcosense.co.uk...
  • Page 5: Do's And Don'ts: Things That Can

    • Read the instructions carefully. • Phone us if you have any difficulties. • Only drive when the AlcoSense says LO and you feel 100%. Any amount of alcohol in your system will affect your ability to drive. • Leave a minimum of 5 minutes between tests. Do not perform more than 5 tests in one hour and no more than 20 tests in 24 hours.
  • Page 6: First Time Setup

    BBR value for your country of use as found in the inside back cover of this manual. If you have any difficulties, feel free to call us. Figure 1 Support: UK 0800 1950088 / IRL 1800 719310 Mon to Fri 0900–1730 info@alcosense.co.uk...
  • Page 7 Figure 2 Please note: the switch is black on the product. Continue to the next step overleaf...
  • Page 8: Install The Batteries And Clean The Sensor

    Never use batteries previously used elsewhere or a mixture of new and used batteries. Although the battery voltage indicator may show OK, under load the battery power may collapse causing inaccurate readings. Support: UK 0800 1950088 / IRL 1800 719310 Mon to Fri 0900–1730 info@alcosense.co.uk...
  • Page 9: Set The Drink Drive Alert Level

    3. Set the Drink Drive Alert Level With only 0.1‰BAC in your system you are 37% more likely to be involved in a fatal accident than when sober. As a result, do not drive with any alcohol in your system. a.
  • Page 10: Understanding The Symbols On Screen

    The breathalyser requires recalibration. Please see the recalibration RECALIBRATE section of the manual. Shows the battery level. Replace the batteries with new good quality batteries when one bar is remaining. Support: UK 0800 1950088 / IRL 1800 719310 Mon to Fri 0900–1730 info@alcosense.co.uk...
  • Page 11: How To Perform A Breath Test

    Do not use drinking straws or similar as the diameter may be different giving a bad fit, or split causing air to escape and reducing the accuracy of your readings. Replacement tubes are inexpensive can be purchased from alcosense.co.uk or an AlcoSense retailer. Figure 4...
  • Page 12 “Wait” symbol while the sensor is heated to operating temperature. The AlcoSense will then beep and the “blow” symbol will flash on the screen. Blow into the breathalyser using a pressure similar to a sigh and keep blowing until it stops beeping (around 6-7 seconds).
  • Page 13: Understanding The Results

    Understanding the Results Description Screen Explanation Zero or Trace Alcohol There is either no alcohol in the sample or such a small amount it is negligible. The Less than 0.1‰BAC reading is well below the legal drink drive limit. Alcohol Present - DO NOT DRIVE Alcohol present, Your are below the limit you set in the but under the limit...
  • Page 14: Maintaining Your Alcosense Breathalyser

    Keep it Clean To keep your AlcoSense in tip top condition we recommend keeping it clean using a soft dry cloth. We recommend keeping your unit safe using the AlcoSense carry case which is sold separately from alcosense.co.uk and AlcoSense retailers.
  • Page 15: Technical Support

    Be Careful Take care not to drop the AlcoSense breathalyser as sudden knocks can affect the unit’s accuracy. If you have dropped your AlcoSense and feel that it is not reading correctly please contact us to arrange to have the unit serviced.
  • Page 16: Troubleshooting

    “RECALIBRATE” is shown on screen Please see the section of the manual on recalibration. If you believe the recalibration alert has been shown prematurely please call us. Support: UK 0800 1950088 / IRL 1800 719310 Mon to Fri 0900–1730 info@alcosense.co.uk...
  • Page 17 I’ve done two breath tests and got different results. This is expected. The first test is the most accurate, if you perform a second test within a few minutes of the first test the breath alcohol levels in your lungs may not have stabilised after the first test, causing the second test to give you a different reading.
  • Page 18: Technical Specifications

    -10˚C to 50˚C Storage conditions Store in a cool dry place out of direct sunlight Calibration Intervals 12 months or 300 tests, whichever comes first Sensor Semi-Conductor Support: UK 0800 1950088 / IRL 1800 719310 Mon to Fri 0900–1730 info@alcosense.co.uk...
  • Page 19 This page is for notes...
  • Page 20: Legal & Warranty

    HOW TO MAKE A WARRANTY CLAIM 3) In order to make a claim of a Defect, you must contact AlcoSense by email or telephone during the Warranty Period via www.AlcoSense.com to explain the Defect and to obtain an RMA number (Return Materials Authorisation) if necessary.
  • Page 21 6) Except for the Limited Warranty and to the maximum extent permitted by applicable law, AlcoSense and its suppliers provide the Hardware “AS IS AND WITH ALL FAULTS”, and hereby disclaim all other warranties and conditions, whether express, implied or statutory, including, but not...
  • Page 22: Common Drink Drive Limits And Blood Breath Ratios

    Germany (Normal Limit) 2100:1 0.50 Holland (Lower Limit) 2100:1 0.20 Holland (Normal Limit) 2100:1 0.50 Hungary 2100:1 0.00 Iceland 2100:1 0.30 Ireland (RoI) (Normal Limit) 2300:1 0.50 Support: UK 0800 1950088 / IRL 1800 719310 Mon to Fri 0900–1730 info@alcosense.co.uk...
  • Page 23 *Limits correct as of May 2019, errors and omissions excluded. Always check the limit with the local road authority in the region before driving. Northern Ireland has proposals to reduce their limit, please check with local road authorities before driving. **The AlcoSense Lite 2 cannot be used to comply with French law.
  • Page 24 UK: 0800 195 0088 Ireland: 1800 719310 Poland: 22 26 39 345 International calls: +44 1628 778885 info@alcosense.com www.alcosense.com © Now Group UK Ltd 2019. This product, packaging and manual includes the registered and unregistered intellectual property of Now Group UK Ltd. www.alcosense.co.uk/ip...

Table of Contents