C-7070 Wide Zoom
5. CCD Black Point And White Point Defect Detect
Adjustment In Lighted
Camera
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100 ± 20 (K)
Luminance: 900 ± 20 (cd/m
Adjusting method:
1. Set the camera 0 cm from the pattern box. (Do not enter
any light.)
2. Double-click on the DscCalDi.exe.
3. Select "CCD Black" on the LCD "Test", and click the "Yes".
4. After the adjustment is completed, the number of defect
will appear.
(When adjustment is failed, "detect_ng BLACK x, y" will
display.)
5. Click the OK.
Ver. 1
C. ADJUSTMENT METHOD
Pattern box
(color viewer)
)
2
6. PAF Adjustment
6-1. Uniform Adjustment
Camera
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100 ± 20 (K)
Luminance: 900 ± 20 (cd/m
Note:
Orient the PAF sensor towards the viewer.
Adjusting method:
1. Set the camera 0 cm from the pattern box.
2. Double-click on the DscCalDi.exe.
3. Click the "PAF Cal". "PAF Calibration Dialog" is opened.
4. Click the "Uniformity".
5. Uniformity adjustment value will appear on the screen.
6. Click the OK.
7. This adjustment is to check whether there is a pixel defi-
ciency in the sensor by viewing the graph that appears on
the camera's LCD. A pixel deficiency or other trouble will
result in fluctuations appearing on the graph.
C-7
Pattern box
(color viewer)
)
2