light shoud be off for 5 seconds.
b) For the units' malfunctins Annex 1
If there's malfunction with the units, this will not affect the run of the complete appliance, but this
can be displayed by the malfunction light, the light flashing frequency is 0.5HZ, the number of
times is according to the malfunction table of the indoor units. When a round of flashing is
finished, the light shoud be off for 10 seconds. Then report according to the order : unit A unit B
unit C unit D, that is, if there's malfunction with several units, then just report the indoor unit
with the highest priority level. Among the unit malfunctions, the priority level of the
communication malfunction is the highest, for others, that appears first will have the priority.
Remarks: in 3 minutes when the compressor stops, the units' malfunctions are not displayed;
the complete appliance's malfunctions are prior to the units' malfunctions.
Annex 1 Malfunction codes of the whole unit
Remarks: under the mode of refrigeration, the malfunctions of each unit's thin pipe temperature
sensor are not reported, under the mode of heating, the malfunctions of each unit's thick pipe
temperature sensor are not reported.
F12
1
Outdoor EEPROM error
2
F1
The protection of IPM
F22
3
Overcurrent protection of AC electricity for the outdoor model
F3
4
Communication fault between the IPM and outdoor PCB
F19
6
Power voltage is too high or low
F4
8
Overheat protection for exhaust temperature
F21
10
Frost-removing temperature sensor failure
F6
12
Ambient temperature sensor failure
F25
13
Exhaust temperature sensor failure
E7
15
Communication fault between indoor and outdoor units
F11
18
deviate from the normal for the compressor
----
19
Loop of the station detect error
E9
21
High work-intense protection
---
24
Overcurrent of the compressor
---
25
Overcurrent protection for single-phase of the compressor
----
36
The socket protect