Faststream Sc 7500 Physical Attributes; Dimensions; Cooling And Airflow; Power - ATTO Technology FastStream SC 5500 Installation And Operation Manual

Fibre channel to sas/sata & fibre channel to fibre channel models storage controller
Hide thumbs Also See for FastStream SC 5500:
Table of Contents

Advertisement

1.2 FastStream SC 7500 Physical Attributes

The ATTO FastStream SC 7500 is a Fibre Channel to SAS/SATA storage controller which can be seamlessly
integrated into an existing storage environment.
The ATTO FastStream SC 7500 is available in a
desktop model, an industry-standard 1U form factor
for easy integration into racks and an embeddable
model. It supports next-generation media and is
equipped to handle the throughputs needed by
advanced disk technologies.
For installation instructions for the 7500 desktop and
1U models, refer to
Install the FastStream
11.
For installation instructions and physical attribute
details for the embeddable model, refer to the ATTO
Embedded Storage Controller Installation and
Operation manual.

Dimensions

Width: 17.31 inches
Length: 9.9 inches
Height: 1.69 inches (1U)
Weight: approximately 8 pounds

Cooling and airflow

Operating Temperature: 5 °C-40 °C
Humidity: 10-90% non-condensing
CAUTION
CAUTION
Do not block the enclosure's vents. The
FastStream does not allow data transfer if
overheating occurs. Ambient air should
not exceed 40 °C.

Power

Input voltage: 100-240 VAC, 2.5A, 47-63 Hz
Battery-backed event log: A rechargeable Lithium
ion battery cell holds the event log memory for up to 30
days. If the FastStream has been disconnected from
power, recharging begins automatically when power is
restored to the system. The battery is fully charged
after 36 hours of continuous power application.
WARNING
WARNING
Risk of explosion if battery is removed
and/or replaced by an incorrect type.
Dispose of used batteries in accordance
with your local environmental regulations.
Explosionsgefahr, wenn die Batterie falsch
entfernt und/oder ersetzt wird. Entsorgen
Sie benutzte Batterien in Übereinstimmung
mit Ihren lokalen
Umweltschutzbestimmungen.
on page

Fibre Channel ports

The four independent 4-Gigabit Fibre Channel ports
connect the FastStream SC 7500 to Fibre Channel
hosts using optical SFP connectors and multimode
fiber optic cable.
Make sure all cables are anchored securely at both
ends with the proper connectors.

SAS/SATA ports

The two (x4) 3-Gb SAS/SATA
ports connect storage devices
into the Storage Area Network
(SAN) using mini SAS 4x cable
plug connectors.

Management ports

Management is provided using the 10/100/1000 base
T Ethernet port accessible from the RJ-45 connector
or the RS-232 serial port using an RJ-11 connector.
(See
Exhibit

Reset/restore factory default switch

To reset the FastStream, briefly insert a tool in the
reset hole in the back panel for less than three
seconds. See
To restore factory defaults, insert the tool in the reset
hole in the back panel for more than four seconds until
the green Ready LED blinks.

LED indicators

The LED indicators can be viewed from the connector
side and the front side of the FastStream. (See
1.2-1
and
LEDs on the connector side are:
Ready/Fault LED lights green to indicate ready,
yellow to show a faulted condition, and is off to indicate
not ready.
1.2-2).
Exhibit
1.2-1.
Exhibit
1.2-3)
Exhibit
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faststream sc 7700Faststream sc 8500Faststream sc 7500

Table of Contents