  • Page 1 PAVIRO End Of Line Slave Module PVA-1WEOL Installation note...
  • Page 3 PAVIRO End Of Line Slave Table of Contents | en Module Table of contents Short information Installation Technical data Standards and compliancy 01-Dec-2016 | 04 | F01U307360...
  • Page 4 The status LED of the module can help to check the installation. Please refer to the documentation of IRIS-Net or the Controller/Router for more details. Parts included Quantity Component PVA-1WEOL Set of screws Installation note 01-Dec-2016 | 04 | F01U307360...
  • Page 5 PAVIRO End Of Line Slave Installation | en Module 2 Installation Before connecting the module, a module address must be set via the DIP switches S2 and S1 (see following illustration). The module address allows for identification of the affected loudspeaker line in case an error (e.g.
  • Page 6 PAVIRO End Of Line Slave en | Installation Module Module address DIP switch S2 DIP switch S1 OFF OFF OFF OFF OFF OFF 0 (not connected) OFF OFF OFF OFF OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF...
  • Page 7 PAVIRO End Of Line Slave Installation | en Module Module address DIP switch S2 DIP switch S1 OFF OFF ON OFF OFF ON OFF ON OFF OFF OFF OFF ON OFF OFF ON OFF OFF Reserved To activate the status LED for five minutes, switch from ON to OFF...
  • Page 8 PAVIRO End Of Line Slave en | Installation Module Status LED Description No voltage supply (e.g. pilot tone deactivated) Slow flashing (2 Hz) Module ready Rapid flashing (10 Hz) Data is being received from EOL master Table 2.2: Status LED for checking installation Caution! Please ensure that all safety regulations are observed.
  • Page 9 PAVIRO End Of Line Slave Technical data | en Module 3 Technical data Power supply 18–22 kHz, 8 V , 20 mW Minimum R (resistance between 1.5 MΩ / 3.0 MΩ (FW 1.1.0 / 1.2.0) speaker line and ground) Maximum C using successive Hardware version 1.1 Firmware version 1.1.0 =...
  • Page 10 PAVIRO End Of Line Slave en | Technical data Module Product dimensions (Width ✕ Height 78 ✕ 15 ✕ 60 mm ✕ Depth) Net weight 30 g Speaker + Filter DC/DC Speaker - Send/ Control Receive Shield / Wire / Ground Address Figure 3.1: Circuit diagram (R and C...
  • Page 11 Ensure that the worst case situation does not exceed the maximum allowed capacitance. A capacitance calculator to check if the capacitance is in the safe zone and an additional application note can be found on the Bosch Security website. 01-Dec-2016 | 04 | F01U307360...
  • Page 12 PAVIRO End Of Line Slave en | Technical data Module Figure 3.2: Wiring diagram C 01-Dec-2016 | 04 | F01U307360...
  • Page 13 PAVIRO End Of Line Slave Standards and compliancy | en Module 4 Standards and compliancy The device meets the following standards (as of November 2015): – IEC 60065 – EN 55103-1 – EN 50130-4 – EN 60945 – – ICES-003 –...
  • Page 16 Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V., 2016...