INSTALLATION Mount the GRP holder in a position so that a released lifebuoy will easily fall into the water. Follow the instructions for the mounting bolts in accordance with the pictures. Make sure that you mount double washers between frame or bulkhead and the GRP holder. Mount the connector box close to the GRP holder.
Page 3
Make sure that the lifebuoy line is not on the outward side of the release cord! This might entangle the lifebuoy in an activation situation. Pull up the release cord through the ERU hole with the pilot line. Secure it with the manual safety pin. 10.
Page 4
TEST OF THE LIFEBUOY RELEASE SYSTEM TESTING THE MECHANICAL RELEASE FUNCTION Remove the manual safety pin holding the release cord. The Lifebuoy will be released and launched from the GRP holder. TESTING THE ELECTRONIC RELEASE FUNCTION BY USING THE EMULATOR HM-0467 Open the enclosure of the Emulator and attach two connection wires to the terminals on the Emulator.
Page 5
2 x 0,75mm2, diameter 8mm. Longer lengths can be supplied on request by additional meter price. Maximum length of the installation is 150m. The Hammar products are designed to handle any voltage drop, so there is no need to increase the cable dimensions more than our recom- mendation.
HM-0610 LifeBuoy Release system, only manual release. HM-0650 LifeBuoy Release System, vacuum pump operated system. ATEX approved products are available, please contact Hammar for further information. SPARE PARTS Part no. HM-0406 Replacement kit for LifeBuoy HM-0620 Lifebuoy metal spring System MkI, ERU electric/ holder only.