FUNCTION DETAILS
Functions
1) Filter sign
2) Cooler room temperature correction
3) Heater room temperature correction
4) Auto restart
5) Indoor room temperature sensor switching function
6) Remote controller signal code
7) External input control
8) Indoor unit fan control for energy saving
1) Filter sign
The indoor unit has a sign to inform the user that it is time to clean the filter. Select the time
setting for the filter sign display interval in the table below according to the amount of dust or
debris in the room. If you do not wish the filter sign to be displayed, select the setting value for
"No indication".
Setting description
Long interval
Short interval
No indication
The filter sign interval time is different according to Indoor unit type as follows.
Setting description
Long interval
Short interval
2) Cooler room temperature correction
Depending on the installed environment, the room temperature sensor may require correction.
The settings may be selected as shown in the table below.
Setting description
Slightly lower control
Lower control
Warmer control
3) Heater room temperature correction
Depending on the installed environment, the room temperature sensor may require correction.
The settings may be changed as shown in the table below.
Setting description
Lower control
Slightly warmer control
Warmer control
Function number
Standard
Compact Wall
Standard
400 hours
1000 hours
200 hours
Function number
Standard
Function number
Standard
- (01 - 29) -
Compact wall
mounted
z
z
z
z
z
z
z
z
(  ... Factory setting)
Setting value
00
01
11
02
03
Mounted
(  ... Factory setting)
Setting value
00
01
30
02
03
(  ... Factory setting)
Setting value
00
01
31
02
03