10. ORDINARY MAINTENANCE

ATTENTION! BEFORE MAINTENANCE OR CLEANING, DISCONNECT THE REFRIGERATOR FROM THE
ELECTRICAL POWER SUPPLY USING THE WALL MAIN CUTOFF SWITCH (fig. 23).
IMPORTANT: During maintenance or cleaning operations, be sure that the light in the working area
is sufficient. If necessary, use an additional source of light. Mind also the hot and moving parts
marked with the relevant symbol. The use of heavy-duty gloves is recommended.
ATTENTION! Front glazing can be opened for cleaning and restocking operations. It is
advisable to carry out these jobs when the sales area is NOT OPEN TO THE PUBLIC.
CLEANING THE CABINET
1) Every week clean the outer surfaces of the showcase with mild soap or detergent in lukewarm
water only. Wipe carefully with a soft cloth. Never clean it using inflammable or scouring agents,
alcohol, acetone or solvents; Do not use detergent containing nonionic surfactants, lemon o vine-
gar ( acetic acid). NEVER CLEAN THE DISPLAY CASE BY THE USE OF WATER JETS (fig. 21). Clean
glass surfaces using glass-cleaning products only. The use of water is not recommended here, as
it may cause scale to build up.
2) Every month clean the cabinet inside surfaces following the instructions provided in the prece-
ding item, only using a non-abrasive sponge (the maximum temperature of the usable water for
the cleaning is of 65°C) and those indicated here below:
• Disconnect the cabinet from the power mains using the wall main cutoff switch (fig. 23).
• Empty the appliance, store its contents in coldrooms or refrigerators that are adequate for kee-
ping the requisite preservation temperature.
• Wait until the showcase has reached ambient temperature and then clean according to the above
instructions. The incorporated drain facilitates the collection of wash water by conveying it directly
outside the cabinet.
• After having carefully checked that the cabinet is completely dry, reassemble it and switch it on.
• Allow a couple of hours before loading the products back again.
NOTE: to ease the cleaning of internal parts, the cabinet is provided with easy-to-remove inner
walls on the air-outlet side (fig. 25). ATTENTION: MAKE SURE THAT THE INNER WALLS ARE PUT
BACK IN PLACE. To clean the base deck it is also possible to turn the fan holder upwards.
3) Defrost the showcase every three months to let the ice that may have formed between the eva-
porator fins melt, since frost may otherwise prevent correct operation. Proceed according to the
instructions for cleaning the inside surfaces at item 2, but allow a longer wait time for the ice to
melt completely.
Any maintenance operation not dealt with above, must be carried out by the authorised after-sales
service or by qualified personnel.

11. EMERGENCY SITUATIONS

1) The cabinet will not start or will not keep on working:
• there may be a general blackout;