INSTRUCTIONS - INTERFIT
PROJECTOR LIFT – FVI and HTI Series
IR GROUP COMMANDS
Each module will require programming via register 75, as per point 15 in document
Example of direct command Connected to 192.168.0.32:3002 – command 20 1 ,would see all
lifter programmed to operate on IR group 1 move to up position
OPERATE IR GROUP
COMMAND
20
23
26
SWITCH GROUP COMMANDS
Example of direct command:
Connected to 192.168.0.32:3001 – command 30 1 using module ID would see the lifter move
to up position
Connected to 192.168.0.32:3001 – command 30 17 using MAF address would see the lifter
move to up position
OPERATE SWITCH GROUP
COMMAND
10
SWITCH Group 1 or 2
13
SWITCH Group 1 or 2
18. MODULE STATUS FEEDBACK
A module status buffer (20 record FIFO) is updated as a automatically generated Send
Register Commands with register number = 0x20 are sent from each module.
The module status buffer contains the Module ID (1 byte), and Module Status (2 bytes)
COMMAND
050
Response from module e.g. 150, 1, 1, 6 – value 6 indicates screen at top
IR GROUP
DESCRIPTION
IR Group 1 or 2
Operate IR Group UP
IR Group 1 or 2
Operate IR Group DOWN
IR Group 1 or 2
Operate IR Group STOP
IR GROUP
DESCRIPTION
Operate Switch Group UP
Operate Switch Group DOWN
COMMAND
VALUE 1
150
Status
Note:
Status=1 is returned if valid data and no further records in the status buffer
Status=2 is returned if valid data and there are still records in status buffer
Status=3 is returned if valid data but the buffer is full (eg may have lost data)
Status=6 is returned if there are no new records
This buffer is updated when screens are moved. It is also updated automatically every 60 seconds.
It needs to be polled regularly to clear the stored data otherwise it will get full and records will be
lost. Even though screens may not be moving the data is being updated even though the status is the
same.
RESPONSE TYPE NO
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
VALUE 2
VALUE 3
Module ID
Module Status Register (0x20)
CONNECT IP MODULE
Moving top
Moving bot
Moving PP1
Moving PP2
Moving PPT
Moving PPB
At TOP
At BOTTOM
At PP1
At PP2
Stopped manual
Error
Spare
Fail-timeout
Fail – current
Rattle
At PPT
At PPB
Continued Over.../